- DETECTION mask with pcodethresh = 0.01 is used for everything except spectral analysis. - Spectral analysis is only available for part of the burst duration. - Refined position calculated manually from image made from T100_start to T0+13.789 s (slew begins) in 15-350 keV, which is what batgrbproduct uses, but somehow it does not find a refined position in this case. # Need to use the special script at /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger555163/special_script to make webpage # single-ish pulse GRB.