- T100, T90, and T50 might be lower limits. T100 starts at T0-182.64 s, which is very close to the beginning of the event data. Therefore, there might be additional emission earlier. - Refined position calculated with time interval and energy band determined by the flight software (T0 to T0+64 s; 15-50 keV).