GRB 220618***A***: Swift-BAT refined analysis S. D. Barthelmy (GSFC), H. A. Krimm (NSF), S. Laha (GSFC/UMBC), A. Y. Lien (U Tampa), C. B. Markwardt (GSFC), D. M. Palmer (LANL), T. Parsotan (GSFC/UMBC), T. Sakamoto (AGU), M. Stamatikos (OSU) (i.e. the Swift-BAT team): Using the data set from T-239 to T+656 sec from the recent telemetry downlink, we report further analysis of BAT GRB 220618***A*** (trigger #1110865) (NAME, et al., GCN Circ. xxxx). The BAT ground-calculated position is RA, Dec = 103.835, -1.490 deg which is RA(J2000) = 06h 55m 20.4s Dec(J2000) = -01d 29' 23.1" with an uncertainty of 0.0 arcmin, (radius, sys+stat, 90% containment). The partial coding was 75%. [Description about the mask-weighted light curve] T90 (15-350 keV) is 318.78 +- 159.04 sec (estimated error including systematics). The time-averaged spectrum from TTBD to TTBD sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 3.04 +- 0.00. The fluence in the 15-150 keV band is 1.2 +- 1.7 x 10^-07 erg/cm2. The 1-sec peak photon flux measured from T+529.77 sec in the 15-150 keV band is 0.6 +- 0.3 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/1110865/BA/