GRB 220701***A***: Swift-BAT refined analysis S. D. Barthelmy (GSFC), H. A. Krimm (NSF), S. Laha (GSFC/UMBC), A. Y. Lien (U Tampa), C. B. Markwardt (GSFC), D. M. Palmer (LANL), T. Parsotan (GSFC/UMBC), T. Sakamoto (AGU), M. Stamatikos (OSU) (i.e. the Swift-BAT team): Using the data set from T-239 to T+963 sec from the recent telemetry downlink, we report further analysis of BAT GRB 220701***A*** (trigger #1114077) (NAME, et al., GCN Circ. xxxx). The BAT ground-calculated position is RA, Dec = 103.794, -1.507 deg which is RA(J2000) = 06h 55m 10.6s Dec(J2000) = -01d 30' 26.7" with an uncertainty of 3.3 arcmin, (radius, sys+stat, 90% containment). The partial coding was 57%. [Description about the mask-weighted light curve] T90 (15-350 keV) is 274.00 +- 51.97 sec (estimated error including systematics). The time-averaged spectrum from TTBD to TTBD sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 2.95 +- 0.00. The fluence in the 15-150 keV band is 3.4 +- 0.0 x 10^-06 erg/cm2. The 1-sec peak photon flux measured from T+29.00 sec in the 15-150 keV band is 0.7 +- 0.2 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/1114077/BA/ ##################################################################################### ## Special note (please do not include this in the email circular): ## Becuase E0 = 7.49186 is outside of the BAT energy range (15-350 keV), ## A simple power-law model is chosen despite delta chi2 > 6. #####################################################################################