GRB 221215***A***: Swift-BAT refined analysis S. D. Barthelmy (GSFC), H. A. Krimm (NSF), S. Laha (GSFC/UMBC), A. Y. Lien (U Tampa), C. B. Markwardt (GSFC), D. M. Palmer (LANL), T. Parsotan (GSFC/UMBC), T. Sakamoto (AGU), M. Stamatikos (OSU) (i.e. the Swift-BAT team): Using the data set from T-240 to T+962 sec from the recent telemetry downlink, we report further analysis of BAT GRB 221215***A*** (trigger #1144538) (NAME, et al., GCN Circ. xxxx). The BAT ground-calculated position is RA, Dec = 54.718, -27.404 deg which is RA(J2000) = 03h 38m 52.4s Dec(J2000) = -27d 24' 15.8" with an uncertainty of 5.0 arcmin, (radius, sys+stat, 90% containment). The partial coding was 100%. [Description about the mask-weighted light curve] T90 (15-350 keV) is 0.59 +- 0.06 sec (estimated error including systematics). The time-averaged spectrum from T+195.84 to T+196.49 sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 0.00 +- 0.00. The fluence in the 15-150 keV band is 4.8 +- 2.2 x 10^-08 erg/cm2. The 1-sec peak photon flux measured from T+195.74 sec in the 15-150 keV band is 0.3 +- 0.2 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/1144538/BA/