GRB 240222***A***: Swift-BAT refined analysis S. D. Barthelmy (GSFC), H. A. Krimm (NSF), S. Laha (GSFC/UMBC), A. Y. Lien (U Tampa), C. B. Markwardt (GSFC), M. J. Moss (GSFC), D. M. Palmer (LANL), T. Parsotan (GSFC), T. Sakamoto (AGU) (i.e. the Swift-BAT team): Using the data set from T-60 to T+243 sec from the recent telemetry downlink, we report further analysis of BAT GRB 240222***A*** (trigger #1216910) (NAME, et al., GCN Circ. xxxx). The BAT ground-calculated position is RA, Dec = 245.471, -15.753 deg which is RA(J2000) = 16h 21m 53.0s Dec(J2000) = -15d 45' 11.9" with an uncertainty of 1.3 arcmin, (radius, sys+stat, 90% containment). The partial coding was 100%. [Description about the mask-weighted light curve] T90 (15-350 keV) is 64.00 +- 0.00 sec (estimated error including systematics). The time-averaged spectrum from T+0.00 to T+64.00 sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 5.64 +- 0.36. The fluence in the 15-150 keV band is 9.7 +- 0.8 x 10^-07 erg/cm2. The 1-sec peak photon flux measured from T+0.00 sec in the 15-150 keV band is 0.5 +- 0.0 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/1216910/BA/