GRB 240302***A***: Swift-BAT refined analysis S. D. Barthelmy (GSFC), H. A. Krimm (NSF), S. Laha (GSFC/UMBC), A. Y. Lien (U Tampa), C. B. Markwardt (GSFC), M. J. Moss (GSFC), D. M. Palmer (LANL), T. Parsotan (GSFC), T. Sakamoto (AGU) (i.e. the Swift-BAT team): Using the data set from T-239 to T+423 sec from the recent telemetry downlink, we report further analysis of BAT GRB 240302***A*** (trigger #1218293) (NAME, et al., GCN Circ. xxxx). The BAT ground-calculated position is RA, Dec = 245.149, -15.529 deg which is RA(J2000) = 16h 20m 35.8s Dec(J2000) = -15d 31' 43.4" with an uncertainty of 0.0 arcmin, (radius, sys+stat, 90% containment). The partial coding was 64%. [Description about the mask-weighted light curve] T90 (15-350 keV) is 5.60 +- 1.41 sec (estimated error including systematics). The time-averaged spectrum from T-233.85 to T-226.63 sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 1.50 +- 0.00. The fluence in the 15-150 keV band is 0.0 +- 0.0 x 10^+00 erg/cm2. The 1-sec peak photon flux measured from T-233.65 sec in the 15-150 keV band is 0.5 +- 0.2 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at https://swift.gsfc.nasa.gov/results/batgrbcat/BAT_refined_circular/1218293