GRB 071031***A***, Swift-BAT refined analysis S. D. Barthelmy (GSFC), W. H. Baumgartner (GSFC/UMBC), J. R. Cummings (GSFC/UMBC), N. Gehrels (GSFC), H. A. Krimm (GSFC/USRA), A. Y. Lien (GSFC/UMBC), C. B. Markwardt (GSFC), D. M. Palmer (LANL), T. Sakamoto (AGU), M. Stamatikos (OSU), T. N. Ukwatta (LANL) (i.e. the Swift-BAT team): Using the data set from T-239 to T+963 sec from the recent telemetry downlink, we report further analysis of BAT GRB 071031***A*** (trigger #295670) (NAME, et al., GCN Circ. xxxx). The BAT ground-calculated position is RA, Dec = 6.396, -58.052 deg which is RA(J2000) = 00h 25m 34.9s Dec(J2000) = -58d 03' 07.6" with an uncertainty of 1.8 arcmin, (radius, sys+stat, 90% containment). The partial coding was 75%. [Description about the mask-weighted light curve] T90 (15-350 keV) is 180.6 +- 30.3 sec (estimated error including systematics). The time-averaged spectrum from T-4.5 to T+192.5 sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 2.35 +- 0.26. The fluence in the 15-150 keV band is 9.0 +- 1.3 x 10^-07 erg/cm2. The 1-sec peak photon flux measured from T+2.56 sec in the 15-150 keV band is 0.5 +- 0.1 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/295670/BA/