GRB 080307***A***, Swift-BAT refined analysis S. D. Barthelmy (GSFC), W. H. Baumgartner (GSFC/UMBC), J. R. Cummings (GSFC/UMBC), N. Gehrels (GSFC), H. A. Krimm (GSFC/USRA), A. Y. Lien (GSFC/UMBC), C. B. Markwardt (GSFC), D. M. Palmer (LANL), T. Sakamoto (AGU), M. Stamatikos (OSU), T. N. Ukwatta (LANL) (i.e. the Swift-BAT team): Using the data set from T-561 to T+1164 sec from the recent telemetry downlink, we report further analysis of BAT GRB 080307***A*** (trigger #305011) (NAME, et al., GCN Circ. xxxx). The BAT ground-calculated position is RA, Dec = 136.632, 35.151 deg which is RA(J2000) = 09h 06m 31.7s Dec(J2000) = +35d 09' 05.0" with an uncertainty of 1.6 arcmin, (radius, sys+stat, 90% containment). The partial coding was 81%. [Description about the mask-weighted light curve] T90 (15-350 keV) is 124.0 +- 23.3 sec (estimated error including systematics). The time-averaged spectrum from T-0.4 to T+140.6 sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 1.70 +- 0.20. The fluence in the 15-150 keV band is 9.3 +- 1.2 x 10^-07 erg/cm2. The 1-sec peak photon flux measured from T+8.56 sec in the 15-150 keV band is 0.4 +- 0.1 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/305011/BA/