GRB 120911***A***, Swift-BAT refined analysis S. D. Barthelmy (GSFC), W. H. Baumgartner (GSFC/UMBC), J. R. Cummings (GSFC/UMBC), N. Gehrels (GSFC), H. A. Krimm (GSFC/USRA), A. Y. Lien (GSFC/UMBC), C. B. Markwardt (GSFC), D. M. Palmer (LANL), T. Sakamoto (AGU), M. Stamatikos (OSU), T. N. Ukwatta (LANL) (i.e. the Swift-BAT team): Using the data set from T-239 to T+963 sec from the recent telemetry downlink, we report further analysis of BAT GRB 120911***A*** (trigger #533268) (NAME, et al., GCN Circ. xxxx). The BAT ground-calculated position is RA, Dec = 357.967, 63.090 deg which is RA(J2000) = 23h 51m 52.0s Dec(J2000) = +63d 05' 24.4" with an uncertainty of 1.6 arcmin, (radius, sys+stat, 90% containment). The partial coding was 23%. [Description about the mask-weighted light curve] T90 (15-350 keV) is 21.5 +- 3.8 sec (estimated error including systematics). The time-averaged spectrum from T-1.6 to T+24.1 sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 1.72 +- 0.16. The fluence in the 15-150 keV band is 1.1 +- 0.1 x 10^-06 erg/cm2. The 1-sec peak photon flux measured from T-0.30 sec in the 15-150 keV band is 2.7 +- 0.3 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/533268/BA/