GRB 141221***A***, Swift-BAT refined analysis S. D. Barthelmy (GSFC), W. H. Baumgartner (GSFC/UMBC), J. R. Cummings (GSFC/UMBC), N. Gehrels (GSFC), H. A. Krimm (GSFC/USRA), A. Y. Lien (GSFC/UMBC), C. B. Markwardt (GSFC), D. M. Palmer (LANL), T. Sakamoto (AGU), M. Stamatikos (OSU), T. N. Ukwatta (LANL) (i.e. the Swift-BAT team): Using the data set from T-240 to T+962 sec from the recent telemetry downlink, we report further analysis of BAT GRB 141221***A*** (trigger #622006) (NAME, et al., GCN Circ. xxxx). The BAT ground-calculated position is RA, Dec = 198.283, 8.198 deg which is RA(J2000) = 13h 13m 07.8s Dec(J2000) = +08d 11' 51.2" with an uncertainty of 1.0 arcmin, (radius, sys+stat, 90% containment). The partial coding was 78%. [Description about the mask-weighted light curve] T90 (15-350 keV) is 36.8 +- 4.1 sec (estimated error including systematics). The time-averaged spectrum from T-24.1 to T+20.3 sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 1.74 +- 0.08. The fluence in the 15-150 keV band is 2.1 +- 0.1 x 10^-06 erg/cm2. The 1-sec peak photon flux measured from T-0.10 sec in the 15-150 keV band is 3.1 +- 0.2 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/622006/BA/