GRB 181026***A***: Swift-BAT refined analysis S. D. Barthelmy (GSFC), J. R. Cummings (CPI), H. A. Krimm (NSF/USRA), A. Y. Lien (GSFC/UMBC), C. B. Markwardt (GSFC), D. M. Palmer (LANL), T. Sakamoto (AGU), M. Stamatikos (OSU), T. N. Ukwatta (LANL) (i.e. the Swift-BAT team): Using the data set from T-239 to T+423 sec from the recent telemetry downlink, we report further analysis of BAT GRB 181026***A*** (trigger #868851) (NAME, et al., GCN Circ. xxxx). The BAT ground-calculated position is RA, Dec = 244.803, -16.087 deg which is RA(J2000) = 16h 19m 12.8s Dec(J2000) = -16d 05' 12.0" with an uncertainty of 1.0 arcmin, (radius, sys+stat, 90% containment). The partial coding was 76%. [Description about the mask-weighted light curve] T90 (15-350 keV) is 346.61 +- 6.87 sec (estimated error including systematics). The time-averaged spectrum from TTBD to TTBD sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 6.61 +- 0.00. The fluence in the 15-150 keV band is 1.8 +- 0.0 x 10^-05 erg/cm2. The 1-sec peak photon flux measured from T+231.18 sec in the 15-150 keV band is 2.0 +- 0.3 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/868851/BA/