GRB 181224***A***, Swift-BAT refined analysis S. D. Barthelmy (GSFC), J. R. Cummings (CPI), H. A. Krimm (NSF/USRA), A. Y. Lien (GSFC/UMBC), C. B. Markwardt (GSFC), D. M. Palmer (LANL), T. Sakamoto (AGU), M. Stamatikos (OSU), T. N. Ukwatta (LANL) (i.e. the Swift-BAT team): Using the data set from T-240 to T+450 sec from the recent telemetry downlink, we report further analysis of BAT GRB 181224***A*** (trigger #878911) (NAME, et al., GCN Circ. xxxx). The BAT ground-calculated position is RA, Dec = 125.949, 6.194 deg which is RA(J2000) = 08h 23m 47.7s Dec(J2000) = +06d 11' 40.0" with an uncertainty of 1.9 arcmin, (radius, sys+stat, 90% containment). The partial coding was 80%. [Description about the mask-weighted light curve] T90 (15-350 keV) is 12.5 +- 4.2 sec (estimated error including systematics). The time-averaged spectrum from T-12.0 to T+3.3 sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 1.27 +- 0.20. The fluence in the 15-150 keV band is 4.9 +- 0.6 x 10^-07 erg/cm2. The 1-sec peak photon flux measured from T+0.48 sec in the 15-150 keV band is 1.0 +- 0.2 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/878911/BA/