batgrbproduct analysis for trigger=946256

batgrbproduct Analysis for Trigger=946256

Analysis Summary

Notes:

======================================================================
                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.46
    Process Start Time (local time): Fri Dec 27 19:52:51 EST 2019
             Host Name: bat1
   Current Working Dir: /local/data/bat1/prebascript/trigger946256/GCN5_download_cron
======================================================================

  Trigger: 00946256      Segment: 000

  BAT Trigger Time: 599032408   [s; MET]
      Trigger Stop: 599032472   [s; MET]
               UTC: 2019-12-26T05:53:03.847380    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 135.861514500973   Dec: -40.2973013757313  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    8.37
     Image Trigger?:     YES
     Rate S/N Ratio:     0  [ if not an image trigger ]
     Image S/N Ratio:    8.37

  Flight Position:   [ source = BAT ]
    RA: 135.861514500973   Dec: -40.2973013757313  [deg; J2000]


  Partial Coding Fraction:     [ including projection effects ]

 
  Angular difference between Flight and Ground position is 0.000000 arcmin
 
  Partial Coding Fraction:     [ including projection effects ]

  Duration
     T90: 64 +/- 101.192885125388
        Measured from: 185.000000119209
                   to: 249.000000119209     [s; relative to TRIGTIME]
     T50: 32 +/- 16
        Measured from: 201.000000119209
                   to: 233.000000119209     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 128.5     
                   to: 129.5     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: 105     
                   to: 265     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     6.174834   3.315519   0.087647   0.183270
           0.094622   0.093941   0.082639   0.085426 [error]
 Peak      0.062500   0.028077  -0.001529   0.004927
           0.008084   0.007681   0.006464   0.006682 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================
 
=== Fluence/Peak Flux Summary ===
 
              Model    Band1    Band2    Band3    Band4    Band5    Total      
                       15-25    25-50   50-100  100-350   15-150   15-350   keV
Fluence   Power-law -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux Power-law -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
Fluence   Cutoff-PL -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux Cutoff-PL -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
Fluence        Band -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux      Band -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
=== Time-averaged spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
 
=== 1-s peak spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
Model      : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index   : photon index: E^-{Ph_index} (minus sign is not included in the index)
Ph_90err   : 90% error of the photon index
Epeak      : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm       : normalization at 50 keV in PL model and at 1 keV in CPL model
Nomr_90err : 90% error of the normalization
chi2       : Chi-Squared
dof        : degree of freedom
 
=== T90/T50 calculation in the 50-300 keV band (BATSE band) using 64 ms lc ===
 
T90 in the 50-300 keV band: 0.000000 sec.
T50 in the 50-300 keV band: 0.000000 sec.
 
=== Table of the duration information ==
 
        Value   tstart    tstop
T100  160.000  105.000  265.000
T90    64.000  185.000  249.000
T50    32.000  201.000  233.000
Peak    1.000  128.500  129.500
  • Click here for the BAT GCN circular template
  • Estimated redshift from machine learning (Ukwatta et al. 2016) - may take a few minutes to calcaulte

    Image

    Pre-slew 15-350 keV image (Event data; bkg subtracted)

     
    Foreground time interval of the image:
    Background time interval of the image:
    

    Lightcurves

    Notes:

    1 s binning

    From T0-310 s to T0+310 s
    From T100_start - 20 s to T100_end + 30 s
    Full time interval

    64 ms binning

    Full time interval
    From T100_start to T100_end
    From T0-5 sec to T0+5 sec

    16 ms binning

    From T100_start-5 s to T100_start+5 s

    8 ms binning

    From T100_start-3 s to T100_start+3 s

    2 ms binning

    From T100_start-1 s to T100_start+1 s

    SN=5 or 10 sec. binning (whichever binning is satisfied first)

    SN=5 or 10 sec. binning (T < 200 sec)

    Spectra

    Notes:

    Time averaged spectrum fit using the pre-slew DRM

    Power-law model
    Time interval is from  105.000 sec. to  265.000 sec.
    Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
           This script tries to add the systematic column to the PHA
           file before doing the fitting                            
    script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
    folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
    
    Cutoff power-law model
    Time interval is from  105.000 sec. to  265.000 sec.
    Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
           This script tries to add the systematic column to the PHA
           file before doing the fitting                            
    script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
    folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
    
    Band function
    Time interval is from  105.000 sec. to  265.000 sec.
    Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
           This script tries to add the systematic column to the PHA
           file before doing the fitting                            
    script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
    folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
    
    Single BB
    Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
           This script tries to add the systematic column to the PHA
           file before doing the fitting                            
    
    Thermal bremsstrahlung (OTTB)
    Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
           This script tries to add the systematic column to the PHA
           file before doing the fitting                            
    
    Double BB
    Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
           This script tries to add the systematic column to the PHA
           file before doing the fitting                            
    

    Peak spectrum fit

    Power-law model
    Time interval is from  128.500 sec. to  129.500 sec.
    Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
           This script tries to add the systematic column to the PHA
           file before doing the fitting                            
    script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
    folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
    
    Cutoff power-law model
    Time interval is from  128.500 sec. to  129.500 sec.
    Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
           This script tries to add the systematic column to the PHA
           file before doing the fitting                            
    script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
    folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
    
    Band function
    Time interval is from  128.500 sec. to  129.500 sec.
    Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
           This script tries to add the systematic column to the PHA
           file before doing the fitting                            
    script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
    folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
    
    Single BB
    Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
           This script tries to add the systematic column to the PHA
           file before doing the fitting                            
    
    Thermal bremsstrahlung (OTTB)
    Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
           This script tries to add the systematic column to the PHA
           file before doing the fitting                            
    
    Double BB
    Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
           This script tries to add the systematic column to the PHA
           file before doing the fitting                            
    

    Pre-slew spectrum (Pre-slew PHA with pre-slew DRM)

    Power-law model
    
    
    Cutoff power-law model
    
    
    Band function
    
    
    
    

    S(25-50 keV) vs. S(50-100 keV) plot

    S(25-50 keV)  = --------
    S(50-100 keV) = --------
    

    T90 vs. Hardness ratio plot

    T90                                   = 64 sec.
    Hardness ratio (energy fluence ratio) = 
    

    Color vs. Color plot

    Count Ratio  (25-50 keV) / (15-25 keV) = 0.536941
    Count Ratio (50-100 keV) / (15-25 keV) = 0.0141942
    

    Mask shadow pattern

    IMX = 0, IMY = 0
    

    TIME vs. PHA plot around the trigger time

    TIME vs. DetID plot around the trigger time

    100 us light curve (15-350 keV)

    Spacecraft aspect plot

    Bright source in the pre-burst/pre-slew/post-slew images

    Pre-burst image of 15-350 keV band

    Time interval of the image:
    -119.000000 -56.898800
    -24.000000 71.800590
     
    # RAcent  DECcent POSerr Theta    Phi  PeakCts   SNR AngSep     Name
    #  [deg]    [deg]    ['] [deg]  [deg]                   [']
    135.6271 -40.4626   38.3  38.9   97.6   0.2989   0.3    7.1	Vela X-1                      
    169.9182 -60.7047    0.0   9.8  102.3  -0.5216  -1.9   12.7	Cen X-3                       
    186.3108 -62.8248   21.7   2.6  142.7   0.1302   0.5   10.0	GX 301-2                      
    138.3460 -65.1319    2.9  20.9   61.6   1.2921   3.9 ------	UNKNOWN                       
    190.8959 -29.6726    3.0  35.3  177.6   1.3080   3.9 ------	UNKNOWN                       
    201.1780 -78.4588    2.9  13.9  -14.6   1.0360   4.0 ------	UNKNOWN                       
      7.5928 -65.4924    3.3  49.5   -5.7   1.8873   3.4 ------	UNKNOWN                       
    225.4711 -19.1339    3.1  51.7 -139.5   4.7648   3.7 ------	UNKNOWN                       
    250.7864 -41.4433    3.8  41.3  -98.6   3.3130   3.0 ------	UNKNOWN                       
    

    Pre-slew background subtracted image of 15-350 keV band

    Time interval of the image:
     
    

    Post-slew image of 15-350 keV band

    Time interval of the image:
    130.000600 303.105100
     
    # RAcent  DECcent POSerr Theta    Phi  PeakCts   SNR AngSep     Name
    #  [deg]    [deg]    ['] [deg]  [deg]                   [']
    135.6095 -40.3924    0.8   0.2   17.1   3.8249  13.8   10.4	Vela X-1                      
    170.1482 -60.7305    9.9  29.3  -85.1  -0.4823  -1.2    8.1	Cen X-3                       
    186.8941 -62.6842   15.7  37.4  -86.8  -0.5047  -0.7    8.3	GX 301-2                      
    121.1363  -8.3015    3.1  34.6  102.9   2.2643   3.7 ------	UNKNOWN                       
    108.8647 -20.9837    3.1  30.0   71.2   1.8814   3.7 ------	UNKNOWN                       
    194.9697 -55.5187    3.7  41.0  -98.6   3.2108   3.1 ------	UNKNOWN                       
    196.3411 -33.2628    2.6  48.0 -129.0   4.8634   4.4 ------	UNKNOWN                       
    
    Plot creation:
    Fri Dec 27 19:54:05 EST 2019