Analysis Summary

Notes:

======================================================================
                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.46
    Process Start Time: Wed Jan 22 23:13:56 EST 2014
             Host Name: batevent1
   Current Working Dir: /local/data/batevent/batevent_reproc/trigger103647
======================================================================

  Trigger: 00103647      Segment: 000

  BAT Trigger Time: 128259002.24   [s; MET]
      Trigger Stop: 128259002.752   [s; MET]
               UTC: 2005-01-24T11:30:02.876080    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 192.87863931207   Dec: 13.0264315169755  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    17
     Image Trigger?:     NO
     Rate S/N Ratio:     42.2729227756965  [ if not an image trigger ]
     Image S/N Ratio:    17

  Analysis Position:   [ source = BAT ]
    RA: 192.87863931207   Dec: 13.0264315169755  [deg; J2000]

  Refined Position:   [ source = BAT pre-slew burst ]
    RA: 192.875882681784   Dec: 13.0408194360131  [deg; J2000]  
        { 12h 51m 30.2s , +13d 02' 26.9" }
         +/- 0.905662046806876 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.308762029304607 [arcmin] (formal 1-sigma fit error)
    SNR: 35.0425161666131
 
  Angular difference between the analysis and refined position is 0.878185 arcmin
 
  Partial Coding Fraction: 0.3007812    [ including projection effects ]

  Duration
     T90: 3.9360000193119 +/- 2.01171369047144
        Measured from: -1.13199999928474
                   to: 2.80400002002716     [s; relative to TRIGTIME]
     T50: 1.88400000333786 +/- 0.384187448567675
        Measured from: 0.204000011086464
                   to: 2.08800001442432     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: -0.096000000834465     
                   to: 0.903999999165535     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: -3.89599999785423     
                   to: 3.06800000369549     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.388205   0.626275   0.573996   0.138226
           0.028062   0.030724   0.027313   0.019497 [error]
 Peak      0.121458   0.263133   0.230848   0.053804
           0.012221   0.014354   0.013864   0.008869 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================
 
 
====== Table of the duration information =============================
 
        Value   tstart    tstop
T100    6.964   -3.896    3.068
T90     3.936   -1.132    2.804
T50     1.884    0.204    2.088
Peak    1.000   -0.096    0.904
 
 
====== Spectral Analysis Summary =====================================
 
Model      : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index   : photon index: E^{Ph_index}
Ph_90err   : 90% error of the photon index
Epeak      : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm       : normalization at 50 keV in both the PL model and CPL model
Nomr_90err : 90% error of the normalization
chi2       : Chi-Squared
dof        : degree of freedo
 
=== Time-averaged spectral analysis ===
(Best model with acceptable fit: CPL)
 
Model Ph_index Ph_90err_low Ph_90err_hi  Epeak  Epeak_90err_low  Epeak_90err_hi  Norm       Nomr_90err_low    Norm_90err_hi    chi2    dof
PL      -1.410    -0.085      0.085       -           -               -         1.81e-02     -9.23e-04          9.23e-04      55.630   57
CPL     -0.694    -0.370      0.403      100.174     -18.189        47.820      3.90e-02     -1.25e-02          2.03e-02      43.840   56
 
 
=== 1-s peak spectral analysis ===
(Best model with acceptable fit: CPL)
 
Model Ph_index Ph_90err_low Ph_90err_hi  Epeak  Epeak_90err_low  Epeak_90err_hi  Norm       Nomr_90err_low    Norm_90err_hi    chi2    dof
PL      -1.313     -0.096     0.096       -           -               -         4.88e-02     -3.02e-03          3.02e-03      78.420   57
CPL     -0.281     -0.437     0.485       91.054     -13.899        28.152      1.50e-01     -5.54e-02          9.97e-02      60.060   56
 
 
=== Fluence/Peak Flux Summary ===
 
              Model    Band1     Band2     Band3     Band4     Band5     Total
                       15-25     25-50    50-100    100-350    15-150    15-350    keV
Fluence         PL   1.48e-07  2.87e-07  4.32e-07  1.41e-06  1.22e-06  2.28e-06   erg/cm2
      90%_error_low -1.37e-08 -1.66e-08 -2.59e-08 -1.74e-07 -6.52e-08 -1.93e-07   erg/cm2
      90%_error_hi   1.41e-08  1.66e-08  2.58e-08  1.89e-07  6.54e-08  2.04e-07   erg/cm2
Peak flux       PL   1.68e+00  1.89e+00  1.52e+00  2.04e+00  5.83e+00  7.12e+00   ph/cm2/s
      90%_error_low -1.81e-01 -1.33e-01 -1.07e-01 -2.72e-01 -3.74e-01 -4.49e-01   ph/cm2/s
      90%_error_hi   1.87e-01  1.32e-01  1.07e-01  2.94e-01  3.75e-01  4.50e-01   ph/cm2/s
 
Fluence        CPL   1.26e-07  3.04e-07  4.65e-07  6.23e-07  1.18e-06  1.52e-06   erg/cm2
      90%_error_low -1.69e-08 -1.93e-08 -3.12e-08 -1.92e-07 -6.89e-08 -1.99e-07   erg/cm2
      90%_error_hi   1.74e-08  1.96e-08  3.16e-08  2.99e-07  6.87e-08  2.97e-07   erg/cm2
Peak flux      CPL   1.34e+00  2.05e+00  1.72e+00  8.86e-01  5.68e+00  5.99e+00   ph/cm2/s
      90%_error_low -2.16e-01 -1.57e-01 -1.37e-01 -2.51e-01 -3.79e-01 -4.57e-01   ph/cm2/s
      90%_error_hi   2.25e-01  1.59e-01  1.40e-01  3.46e-01  3.80e-01  4.92e-01   ph/cm2/s
 
======================================================================