====================================================================== BAT GRB EVENT DATA PROCESSING REPORT Process Script Ver: batgrbproduct v2.46 Process Start Time (local time): Wed Jan 22 22:37:20 EST 2014 Host Name: batevent1 Current Working Dir: /local/data/batevent/batevent_reproc/trigger112453 ====================================================================== Trigger: 00112453 Segment: 000 BAT Trigger Time: 133523635.584 [s; MET] Trigger Stop: 133523636.096 [s; MET] UTC: 2005-03-26T09:53:56.135600 [includes UTCF correction] Where From?: TDRSS position message BAT RA: 6.85721390690823 Dec: -71.375078177145 [deg; J2000] Catalogged Source?: NO Point Source?: YES GRB Indicated?: YES [ by BAT flight software ] Image S/N Ratio: 21 Image Trigger?: NO Rate S/N Ratio: 116.1034021896 [ if not an image trigger ] Image S/N Ratio: 21 Analysis Position: [ source = BAT ] RA: 6.85721390690823 Dec: -71.375078177145 [deg; J2000] Refined Position: [ source = BAT pre-slew burst ] RA: 6.88115047028435 Dec: -71.3744347753356 [deg; J2000] { 00h 27m 31.5s , -71d 22' 28.0" } +/- 0.545401932441427 [arcmin] (estimated 90% radius based on SNR) +/- 0.163369186079349 [arcmin] (formal 1-sigma fit error) SNR: 72.3165034317991 Angular difference between Flight and Ground position is 0.460309 arcmin Partial Coding Fraction: 0.4804688 [ including projection effects ] Duration T90: 29.440000012517 +/- 1.13471053573939 Measured from: -5.08400000631809 to: 24.3560000061989 [s; relative to TRIGTIME] T50: 19.3880000114441 +/- 0.138679478372513 Measured from: 0.703999996185303 to: 20.0920000076294 [s; relative to TRIGTIME] Fluence Peak Flux (peak 1 second) Measured from: -0.0800000131130219 to: 0.919999986886978 [s; relative to TRIGTIME] Total Fluence Measured from: -9.84000000357628 to: 32.4239999949932 [s; relative to TRIGTIME] Band 1 Band 2 Band 3 Band 4 15-25 25-50 50-100 100-350 keV Total 2.887378 4.613173 4.233984 1.238749 0.046974 0.053397 0.051521 0.044201 [error] Peak 0.270390 0.518760 0.582673 0.203919 0.010955 0.013988 0.014992 0.011322 [error] [ fluence units of on-axis counts / fully illuminated detector ] ======================================================================