#XSPEC version: 12.9.0c #Build Date/Time: Wed Jul 29 15:14:04 2015 # !XSPEC12>show; # #XSPEC version: 12.9.0c # #Mon Dec 28 20:50:57 2015 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue # Always calculate parameter derivatives using full (slower) numerical differentiation: No # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-unknown-linux-gnu-libc2.12/../spectral/modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Energy # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger151131/remake_spec_cflux/spec_20ms_peak/sw00151131000b_20ms_peak.rsp associated with spectrum 1 source 1 # energies: 204 channels: 10 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger151131/remake_spec_cflux/spec_20ms_peak/sw00151131000b_20ms_peak.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger151131/remake_spec_cflux/spec_20ms_peak/sw00151131000b_20ms_peak.pha #Net count rate (cts/s) for Spectrum:1 2.443e-01 +/- 6.084e-02 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 1-10 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 0.02 sec # Using fit statistic: chi # Using test statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger151131/remake_spec_cflux/spec_20ms_peak/sw00151131000b_20ms_peak.rsp for Source 1 # # Spectral data counts: 0.00488577 # Model predicted rate: 0.170853 # # #Current model list: # #======================================================================== #Model cpflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cpflux Emin keV 15.0000 frozen # 2 1 cpflux Emax keV 350.000 frozen # 3 1 cpflux Flux 1.83644 +/- 2.02906 # 4 2 cutep50 a 0.916898 +/- 2.04782 # 5 2 cutep50 b 9999.35 +/- 6.57349E+06 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared = 12.43 using 10 PHA bins. # #Test statistic : Chi-Squared = 12.43 using 10 PHA bins. # Reduced chi-squared = 1.775 for 7 degrees of freedom # Null hypothesis probability = 8.741023e-02 # Weighting method: standard # !XSPEC12>error 3; # Parameter Confidence Range (2.706) #***Warning: Zero alpha-matrix diagonal element for parameter 4 #***Warning: Zero alpha-matrix diagonal element for parameter 5 # Parameter 4 is pegged at 0.916898 due to zero or negative pivot element, likely # caused by the fit being insensitive to the parameter. # Parameter 5 is pegged at 9999.35 due to zero or negative pivot element, likely # caused by the fit being insensitive to the parameter. # #***XSPEC Error: No variable parameters for fit # Fit error occurred during lower bound error calculation. # 3 0 3.35512 (-1.83676,1.51836) # !XSPEC12>error 4; # Parameter Confidence Range (2.706) #Apparent non-monotonicity in statistic space detected. #Current bracket values -0.554031, -1.23501 #and delta stat 0.354609, 4.05862 #but latest trial -1.02971 gives 4.94132 #Suggest that you check this result using the steppar command. # #***Warning: Number of trials exceeded before convergence. #Current trial values 4.29924, 4.29931 #and delta statistic 0.240537, 23.5171 # # 4 -0.89452 4.29925 (-1.81084,3.38293) # !XSPEC12>error 5; # Parameter Confidence Range (2.706) # #***XSPEC Error: Unable to fit when starting with fit statistic = NaN #Error occurred during lower bound error calculation. # #Fit statistic : Chi-Squared = 12.43 using 10 PHA bins. # #Test statistic : Chi-Squared = 12.43 using 10 PHA bins. # Reduced chi-squared = 1.775 for 7 degrees of freedom # Null hypothesis probability = 8.741111e-02 # Current data and model not fit yet. # !XSPEC12> @/local/data/bat1/alien/Swift_3rdBATcatalog/event/scripts/test_cflux/bat_cutpow_cpflux_15_150kev_fit.xcm # !XSPEC12>log none; #