Notes:

Time averaged spectrum fit using the average DRM

Power-law model
Time interval is from  -16.504 sec. to  132.676 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.0164     ( -0.150811   0.154898 )
Norm@50keV  : 8.42845E-04    ( -7.16296e-05   7.13715e-05 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          57.60 using 59 PHA bins.
# Reduced chi-squared =          1.011 for     57 degrees of freedom 
# Null hypothesis probability =   4.526863e-01
 
Photon flux (15-150 keV)    in 149.2 sec: 9.71255E-02 ( -0.0084438  0.0084755 ) ph/cm2/s
Energy fluence (15-150 keV)             : 1.35216e-06 ( -1.22322e-07  1.23065e-07 ) ergs/cm2
 
Cutoff power-law model
Time interval is from  -16.504 sec. to  132.676 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -0.839032     ( -0.309425   0.624286 )
Epeak [keV] : 378.049      ( -378.049 -378.049 )
Norm@50keV  : 1.00959E-03    ( -0.000227436   0.000839901 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          57.31 using 59 PHA bins.
# Reduced chi-squared =          1.023 for     56 degrees of freedom 
# Null hypothesis probability =   4.261556e-01
 
Photon flux (15-150 keV)    in 149.2 sec: 9.63079E-02 ( -0.0088368  0.0088131 ) ph/cm2/s
Energy fluence (15-150 keV)             : 1.33958e-06 ( -1.301e-07  1.28936e-07 ) ergs/cm2
 

1-s peak spectrum fit

Power-law model
Time interval is from   -7.856 sec. to   -6.856 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.01741     ( -0.372741   0.394405 )
Norm@50keV  : 4.01973E-03    ( -0.000906038   0.000903127 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          50.13 using 59 PHA bins.
# Reduced chi-squared =         0.8795 for     57 degrees of freedom 
# Null hypothesis probability =   7.284068e-01
 
Photon flux (15-150 keV)    in 1 sec: 0.463246 ( -0.105704  0.106177 ) ph/cm2/s
Energy fluence (15-150 keV)             : 4.32056e-08 ( -1.05212e-08  1.06921e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from   -7.856 sec. to   -6.856 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: 0.0703312     ( -1.25964   2.66645 )
Epeak [keV] : 105.184      (   )
Norm@50keV  : 1.26381E-02    (     )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          48.80 using 59 PHA bins.
# Reduced chi-squared =         0.8715 for     56 degrees of freedom 
# Null hypothesis probability =   7.414508e-01
 
Photon flux (15-150 keV)    in 1 sec: 0.442542 ( -0.111988  0.110911 ) ph/cm2/s
Energy fluence (15-150 keV)             : 4.04045e-08 ( -1.14117e-08  1.16274e-08 ) ergs/cm2
 

Time-resolved spectra