#XSPEC version: 12.9.0c #Build Date/Time: Wed Jul 29 15:14:04 2015 # !XSPEC12>show; # #XSPEC version: 12.9.0c # #Mon Dec 28 00:19:05 2015 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue # Always calculate parameter derivatives using full (slower) numerical differentiation: No # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-unknown-linux-gnu-libc2.12/../spectral/modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Energy # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger255029/remake_spec_cflux/spec_time_resolved//resolved_spec_10/sw00255029000b_avg.rsp associated with spectrum 1 source 1 # energies: 204 channels: 80 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger255029/remake_spec_cflux/spec_time_resolved//resolved_spec_10/sw00255029000b_avg.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger255029/remake_spec_cflux/spec_time_resolved//resolved_spec_10/sw00255029000b_avg.pha #Net count rate (cts/s) for Spectrum:1 3.393e-02 +/- 2.891e-03 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 4-62 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 9.688 sec # Using fit statistic: chi # Using test statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger255029/remake_spec_cflux/spec_time_resolved//resolved_spec_10/sw00255029000b_avg.rsp for Source 1 # # Spectral data counts: 0.328686 # Model predicted rate: 3.14408E-02 # # #Current model list: # #======================================================================== #Model cflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cflux Emin keV 15.0000 frozen # 2 1 cflux Emax keV 350.000 frozen # 3 1 cflux lg10Flux cgs -7.30564 +/- 0.261620 # 4 2 cutep50 a 1.10129 +/- 0.570439 # 5 2 cutep50 b 9962.49 +/- 1.64508E+06 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared = 61.67 using 59 PHA bins. # #Test statistic : Chi-Squared = 61.67 using 59 PHA bins. # Reduced chi-squared = 1.101 for 56 degrees of freedom # Null hypothesis probability = 2.805640e-01 # Weighting method: standard # !XSPEC12>error 3; # Parameter Confidence Range (2.706) # 3 -7.46928 -7.16146 (-0.163652,0.144172) # !XSPEC12>error 4; # Parameter Confidence Range (2.706) # Warning: renorm - no variable model to allow renormalization # Parameters #Chi-Squared |beta|/N Lvl 3:lg10Flux 4:a 5:b #59.5357 664.301 -1 -8.00293 2.03971 14.5444 #======================================== # Variances and Principal Axes # 3 4 5 # 1.3022E-13| -0.0000 -1.0000 0.0000 # 2.6319E-02| 1.0000 -0.0000 0.0098 # 3.0704E+05| 0.0098 -0.0000 -1.0000 #---------------------------------------- # #==================================== # Covariance Matrix # 1 2 3 # 2.968e+01 -1.174e-02 -3.017e+03 # -1.174e-02 4.647e-06 1.194e+00 # -3.017e+03 1.194e+00 3.070e+05 #------------------------------------ # #======================================================================== #Model cflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cflux Emin keV 15.0000 frozen # 2 1 cflux Emax keV 350.000 frozen # 3 1 cflux lg10Flux cgs -8.00293 +/- 5.44813 # 4 2 cutep50 a 2.03971 +/- 2.15572E-03 # 5 2 cutep50 b 14.5444 +/- 554.084 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # #Fit statistic : Chi-Squared = 59.54 using 59 PHA bins. # #Test statistic : Chi-Squared = 59.54 using 59 PHA bins. # Reduced chi-squared = 1.063 for 56 degrees of freedom # Null hypothesis probability = 3.482571e-01 #***Warning: New best fit found, fit parameters will be set to new values. #Apparent non-monotonicity in statistic space detected. #Current bracket values 2.01358, 1.98297 #and delta stat 0.0397234, 27.3058 #but latest trial 1.99828 gives 28.001 #Suggest that you check this result using the steppar command. # Warning: renorm - no variable model to allow renormalization # Parameters #Chi-Squared |beta|/N Lvl 3:lg10Flux 4:a 5:b #59.525 26.8716 0 -8.00757 2.04680 17.1013 #======================================== # Variances and Principal Axes # 3 4 5 # 2.1867E-12| -0.0000 -1.0000 0.0000 # 2.6292E-02| 1.0000 -0.0000 0.0083 # 4.3171E+05| 0.0083 -0.0000 -1.0000 #---------------------------------------- # #==================================== # Covariance Matrix # 1 2 3 # 2.980e+01 -4.886e-02 -3.585e+03 # -4.886e-02 8.018e-05 5.883e+00 # -3.585e+03 5.883e+00 4.317e+05 #------------------------------------ # #======================================================================== #Model cflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cflux Emin keV 15.0000 frozen # 2 1 cflux Emax keV 350.000 frozen # 3 1 cflux lg10Flux cgs -8.00757 +/- 5.45911 # 4 2 cutep50 a 2.04680 +/- 8.95444E-03 # 5 2 cutep50 b 17.1013 +/- 657.021 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # #Fit statistic : Chi-Squared = 59.52 using 59 PHA bins. # #Test statistic : Chi-Squared = 59.52 using 59 PHA bins. # Reduced chi-squared = 1.063 for 56 degrees of freedom # Null hypothesis probability = 3.486160e-01 #***Warning: New best fit found, fit parameters will be set to new values. #Apparent non-monotonicity in statistic space detected. #Current bracket values 2.00382, 1.98788 #and delta stat 0.0653713, 27.5135 #but latest trial 1.99585 gives 27.9371 #Suggest that you check this result using the steppar command. # Warning: renorm - no variable model to allow renormalization # Parameters #Chi-Squared |beta|/N Lvl 3:lg10Flux 4:a 5:b #59.5028 1.77433 0 -8.01693 2.06153 22.3740 #======================================== # Variances and Principal Axes # 3 4 5 # 9.6241E-11| -0.0003 -1.0000 0.0001 # 2.6192E-02| 1.0000 -0.0003 0.0062 # 7.5954E+05| 0.0062 -0.0001 -1.0000 #---------------------------------------- # #==================================== # Covariance Matrix # 1 2 3 # 2.933e+01 -3.293e-01 -4.718e+03 # -3.293e-01 3.701e-03 5.302e+01 # -4.718e+03 5.302e+01 7.595e+05 #------------------------------------ # #======================================================================== #Model cflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cflux Emin keV 15.0000 frozen # 2 1 cflux Emax keV 350.000 frozen # 3 1 cflux lg10Flux cgs -8.01693 +/- 5.41571 # 4 2 cutep50 a 2.06153 +/- 6.08394E-02 # 5 2 cutep50 b 22.3740 +/- 871.500 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # #Fit statistic : Chi-Squared = 59.50 using 59 PHA bins. # #Test statistic : Chi-Squared = 59.50 using 59 PHA bins. # Reduced chi-squared = 1.063 for 56 degrees of freedom # Null hypothesis probability = 3.493584e-01 #***Warning: New best fit found, fit parameters will be set to new values. #Apparent non-monotonicity in statistic space detected. #Current bracket values 2.01477, 1.96145 #and delta stat 0.0707477, 26.3011 #but latest trial 1.98811 gives 27.527 #Suggest that you check this result using the steppar command. # Warning: renorm - no variable model to allow renormalization # Parameters #Chi-Squared |beta|/N Lvl 3:lg10Flux 4:a 5:b #59.4133 1.8248 -1 -8.05455 2.12221 43.5689 #======================================== # Variances and Principal Axes # 3 4 5 # 3.8337E-08| -0.0053 -1.0000 0.0007 # 2.5767E-02| 1.0000 -0.0053 0.0028 # 1.2973E+06| 0.0028 -0.0007 -1.0000 #---------------------------------------- # #==================================== # Covariance Matrix # 1 2 3 # 1.035e+01 -2.724e+00 -3.659e+03 # -2.724e+00 7.187e-01 9.656e+02 # -3.659e+03 9.656e+02 1.297e+06 #------------------------------------ # #======================================================================== #Model cflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cflux Emin keV 15.0000 frozen # 2 1 cflux Emax keV 350.000 frozen # 3 1 cflux lg10Flux cgs -8.05455 +/- 3.21653 # 4 2 cutep50 a 2.12221 +/- 0.847746 # 5 2 cutep50 b 43.5689 +/- 1139.00 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # #Fit statistic : Chi-Squared = 59.41 using 59 PHA bins. # #Test statistic : Chi-Squared = 59.41 using 59 PHA bins. # Reduced chi-squared = 1.061 for 56 degrees of freedom # Null hypothesis probability = 3.523705e-01 #***Warning: New best fit found, fit parameters will be set to new values. #***Warning: *** 3 point fit failed during interpolation *** #Upper bound error calculation is invalid. # 4 0.956235 2.12221 (-1.16598,0) # !XSPEC12>error 5; # Parameter Confidence Range (2.706) # #***XSPEC Error: Unable to fit when starting with fit statistic = NaN #Error occurred during lower bound error calculation. # #Fit statistic : Chi-Squared = 59.41 using 59 PHA bins. # #Test statistic : Chi-Squared = 59.41 using 59 PHA bins. # Reduced chi-squared = 1.061 for 56 degrees of freedom # Null hypothesis probability = 3.523705e-01 # Current data and model not fit yet. # !XSPEC12> @/local/data/bat1/alien/Swift_3rdBATcatalog/event/scripts/test_cflux/bat_cutpow_cflux_15_150kev_fit.xcm # !XSPEC12>log none; #