Notes:

Time averaged spectrum fit using the average DRM

Power-law model
Time interval is from  -57.324 sec. to  400.776 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.64619     ( -0.0764155   0.0760207 )
Norm@50keV  : 1.38642E-03    ( -5.70808e-05   5.68578e-05 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          70.85 using 59 PHA bins.
# Reduced chi-squared =          1.243 for     57 degrees of freedom 
# Null hypothesis probability =   1.026738e-01
 
Photon flux (15-150 keV)    in 458.1 sec: 0.180812 ( -0.007699  0.007728 ) ph/cm2/s
Energy fluence (15-150 keV)             : 5.9099e-06 ( -2.56885e-07  2.5804e-07 ) ergs/cm2
 
Cutoff power-law model
Time interval is from  -57.324 sec. to  400.776 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.57136     ( -0.111465   0.295374 )
Epeak [keV] : 264.288      ( -421.204 -526.358 )
Norm@50keV  : 1.50895E-03    ( -0.000112974   0.000535557 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          71.01 using 59 PHA bins.
# Reduced chi-squared =          1.268 for     56 degrees of freedom 
# Null hypothesis probability =   8.533757e-02
 
Photon flux (15-150 keV)    in 458.1 sec: 0.180369 ( -0.008321  0.008026 ) ph/cm2/s
Energy fluence (15-150 keV)             : 5.89185e-06 ( -2.88729e-07  2.71546e-07 ) ergs/cm2
 

1-s peak spectrum fit

Power-law model
Time interval is from  -53.100 sec. to  -52.100 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -0.868598     ( -0.115733   0.118438 )
Norm@50keV  : 1.74229E-02    ( -0.00120151   0.00119565 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          67.10 using 59 PHA bins.
# Reduced chi-squared =          1.177 for     57 degrees of freedom 
# Null hypothesis probability =   1.692336e-01
 
Photon flux (15-150 keV)    in 1 sec: 1.99964 ( -0.1371  0.13729 ) ph/cm2/s
Energy fluence (15-150 keV)             : 1.97984e-07 ( -1.42075e-08  1.42574e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from  -53.100 sec. to  -52.100 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -0.474669     ( -0.435403   0.539604 )
Epeak [keV] : 229.443      ( -99.2942 -229.46 )
Norm@50keV  : 2.58043E-02    ( -0.00896663   0.0174982 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          65.17 using 59 PHA bins.
# Reduced chi-squared =          1.164 for     56 degrees of freedom 
# Null hypothesis probability =   1.880417e-01
 
Photon flux (15-150 keV)    in 1 sec: 1.97299 ( -0.14108  0.14107 ) ph/cm2/s
Energy fluence (15-150 keV)             : 1.95016e-07 ( -1.50087e-08  1.48828e-08 ) ergs/cm2
 

Time-resolved spectra