====================================================================== BAT GRB EVENT DATA PROCESSING REPORT Process Script Ver: batgrbproduct v2.46 Process Start Time (local time): Mon Jan 20 01:13:48 EST 2014 Host Name: batevent1 Current Working Dir: /local/data/batevent/batevent_reproc/trigger313417 ====================================================================== Trigger: 00313417 Segment: 000 BAT Trigger Time: 234511649.856 [s; MET] Trigger Stop: 234511650.88 [s; MET] UTC: 2008-06-07T06:07:27.008340 [includes UTCF correction] Where From?: TDRSS position message BAT RA: 194.967287472106 Dec: 15.9004689525493 [deg; J2000] Catalogged Source?: NO Point Source?: YES GRB Indicated?: YES [ by BAT flight software ] Image S/N Ratio: 17.87 Image Trigger?: NO Rate S/N Ratio: 238.88490952758 [ if not an image trigger ] Image S/N Ratio: 17.87 Analysis Position: [ source = BAT ] RA: 194.967287472106 Dec: 15.9004689525493 [deg; J2000] Refined Position: [ source = BAT pre-slew burst ] RA: 194.96360541938 Dec: 15.9101271928674 [deg; J2000] { 12h 59m 51.3s , +15d 54' 36.5" } +/- 0.896855558096024 [arcmin] (estimated 90% radius based on SNR) +/- 0.286990466310308 [arcmin] (formal 1-sigma fit error) SNR: 35.5351096657511 Angular difference between Flight and Ground position is 0.617216 arcmin Partial Coding Fraction: 0.1113281 [ including projection effects ] Duration T90: 78.972000002861 +/- 3.04169689285327 Measured from: -2.99599999189377 to: 75.9760000109673 [s; relative to TRIGTIME] T50: 22.5799999833107 +/- 1.68855913334988 Measured from: 1.70800000429153 to: 24.2879999876022 [s; relative to TRIGTIME] Fluence Peak Flux (peak 1 second) Measured from: 1.50400000810623 to: 2.50400000810623 [s; relative to TRIGTIME] Total Fluence Measured from: -5.96000000834465 to: 155.840000003576 [s; relative to TRIGTIME] Band 1 Band 2 Band 3 Band 4 15-25 25-50 50-100 100-350 keV Total 7.651197 11.876875 11.482594 4.147420 0.132098 0.158146 0.160673 0.127372 [error] Peak 0.369364 0.895090 1.165779 0.497568 0.028047 0.039659 0.047695 0.037801 [error] [ fluence units of on-axis counts / fully illuminated detector ] ======================================================================