#XSPEC version: 12.9.0c #Build Date/Time: Wed Jul 29 15:14:04 2015 # !XSPEC12>show; # #XSPEC version: 12.9.0c # #Sat Dec 26 18:43:29 2015 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue # Always calculate parameter derivatives using full (slower) numerical differentiation: No # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-unknown-linux-gnu-libc2.12/../spectral/modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Energy # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger335715/remake_spec_cflux/spec_20ms_peak/sw00335715000b_20ms_peak.rsp associated with spectrum 1 source 1 # energies: 204 channels: 10 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger335715/remake_spec_cflux/spec_20ms_peak/sw00335715000b_20ms_peak.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger335715/remake_spec_cflux/spec_20ms_peak/sw00335715000b_20ms_peak.pha #Net count rate (cts/s) for Spectrum:1 3.824e-01 +/- 1.236e-01 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 1-10 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 0.02 sec # Using fit statistic: chi # Using test statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger335715/remake_spec_cflux/spec_20ms_peak/sw00335715000b_20ms_peak.rsp for Source 1 # # Spectral data counts: 0.00764889 # Model predicted rate: 0.342195 # # #Current model list: # #======================================================================== #Model cpflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cpflux Emin keV 15.0000 frozen # 2 1 cpflux Emax keV 150.000 frozen # 3 1 cpflux Flux 2.73991 +/- 0.987531 # 4 2 cutep50 a 1.00216 +/- 2.39213 # 5 2 cutep50 b 9999.36 +/- 7.89154E+06 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared = 10.63 using 10 PHA bins. # #Test statistic : Chi-Squared = 10.63 using 10 PHA bins. # Reduced chi-squared = 1.518 for 7 degrees of freedom # Null hypothesis probability = 1.557622e-01 # Weighting method: standard # !XSPEC12>error 3; # Parameter Confidence Range (2.706) # 3 1.19604 4.27295 (-1.54129,1.53562) # !XSPEC12>error 4; # Parameter Confidence Range (2.706) # Warning: renorm - no variable model to allow renormalization # Parameters #Chi-Squared |beta|/N Lvl 3:Flux 4:a 5:b #9.57515 0.180698 -1 0.409717 -2.96050 9999.36 #9.57267 0.110156 -1 0.396927 -2.97774 9999.35 #======================================== # Variances and Principal Axes # 3 4 5 # 7.0506E-03| -0.6865 0.7272 -0.0000 # 6.0677E-01| 0.7272 0.6865 -0.0000 # 3.1524E+10| 0.0000 0.0001 1.0000 #---------------------------------------- # #==================================== # Covariance Matrix # 1 2 3 # 2.063e+00 1.344e+01 2.342e+05 # 1.344e+01 9.951e+01 1.769e+06 # 2.342e+05 1.769e+06 3.152e+10 #------------------------------------ # #======================================================================== #Model cpflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cpflux Emin keV 15.0000 frozen # 2 1 cpflux Emax keV 150.000 frozen # 3 1 cpflux Flux 0.396927 +/- 1.43647 # 4 2 cutep50 a -2.97774 +/- 9.97546 # 5 2 cutep50 b 9999.35 +/- 1.77549E+05 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # #Fit statistic : Chi-Squared = 9.57 using 10 PHA bins. # #Test statistic : Chi-Squared = 9.57 using 10 PHA bins. # Reduced chi-squared = 1.37 for 7 degrees of freedom # Null hypothesis probability = 2.141102e-01 #***Warning: New best fit found, fit parameters will be set to new values. #Apparent non-monotonicity in statistic space detected. #Current bracket values -2.97774, -11.578 #and delta stat 0, 3.41499 #but latest trial -10.3756 gives 3.41589 #Suggest that you check this result using the steppar command. # #***XSPEC Error: A fit statistic = NaN was encountered, possibly from model calculation error. Fit unable to continue #Error occurred during upper bound error calculation. # #Fit statistic : Chi-Squared = 9.57 using 10 PHA bins. # #Test statistic : Chi-Squared = 9.57 using 10 PHA bins. # Reduced chi-squared = 1.37 for 7 degrees of freedom # Null hypothesis probability = 2.141102e-01 # Current data and model not fit yet. # !XSPEC12> @/local/data/bat1/alien/Swift_3rdBATcatalog/event/scripts/test_cflux/bat_cutpow_cpflux_15_25kev_fit.xcm # !XSPEC12>log none; #