#XSPEC version: 12.8.2
#Build Date/Time: Thu Jul  3 19:14:55 2014
#
!XSPEC12> show
#
#XSPEC version: 12.8.2
#
#Sun May 31 04:47:29 2015
# Auto-saving is done after every command.
# Fit statistic in use: Chi-Squared
# Minimization technique: Levenberg-Marquardt
#    Convergence criterion = 0.01
#    Parameter fit deltas: 0.01 * parValue
# Always calculate parameter derivatives using full (slower) numerical differentiation: No
# Querying disabled - will not continue fitting.
# Prefit-renorming enabled.
# Solar abundance table: angr
# Photoionization Cross-Section Table:
#    bcmc:  Balucinska-Church and McCammon, 1998
# Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73
# Model data directory: /software/lheasoft/release/x86_64-unknown-linux-gnu-libc2.12/../spectral/modelData/
# Plot settings:
#   Showing of individual additive components is OFF.
#   Showing of background spectra is OFF.
#   Effective area normalization is OFF.
#   Current unit settings:
#      Energy     = keV
#      Wavelength = angstrom, with Y-Axis displayed per Hz
#   X-Axis data display mode: Channels
#   Spectra plots will be shifted to source frame by redshift value z: 0
#   Device: /null
#   Plotting of line IDs is OFF.
#   Splashpage is ON.
#   xlog for data plots is ON.
#   ylog for data plots is OFF.
#
#   Default plot rebin settings for all plot groups:
#   Min. Signif.   Max. # Bins   Error Type
#        0.00000             1         quad
#
# Responses read: 
#   ../sw00345127000b_preslew.rsp associated with spectrum 1 source 1
#      energies: 204 channels: 80
# Distinct RMF files: 
#     ../sw00345127000b_preslew.rsp
#
#1 file 1 spectrum 
#Spectrum 1  Spectral Data File: ../sw00345127000b_preslew.pha
#Net count rate (cts/s) for Spectrum:1  1.772e-01 +/- 2.075e-02
# Assigned to Data Group 1 and Plot Group 1
#  Noticed Channels:  4-62
#  Telescope: SWIFT Instrument: BAT  Channel Type: PI
#  Exposure Time: 0.624 sec
# Using fit statistic: chi
# Using test statistic: chi
# Using Response (RMF) File            ../sw00345127000b_preslew.rsp for Source 1
#
# Spectral data counts: 0.110552
# Model predicted rate: 0.181268
#
#
#Current model list:
#
#========================================================================
#Model npow<1> Source No.: 1   Active/On
#Model Model Component  Parameter  Unit     Value
# par  comp
#   1    1   npow       PhoIndex            0.915351     +/-  0.196902     
#   2    1   npow       enorm      keV      50.0000      frozen
#   3    1   npow       norm                1.30437E-02  +/-  1.48924E-03  
#________________________________________________________________________
#
#   Using energies from responses.
#
#Fit statistic : Chi-Squared =          46.63 using 59 PHA bins.
#
#Test statistic : Chi-Squared =          46.63 using 59 PHA bins.
# Reduced chi-squared =         0.8181 for     57 degrees of freedom 
# Null hypothesis probability =   8.348331e-01
# Weighting method: standard
#
!XSPEC12> flux 20.0 50.0
# Model Flux     0.575 photons (3.0339e-08 ergs/cm^2/s) range (20.000 - 50.000 keV)
#
!XSPEC12> flux 50.0 150.0
# Model Flux   0.75086 photons (1.1042e-07 ergs/cm^2/s) range (50.000 - 150.00 keV)
#
!XSPEC12> error 1
# Parameter   Confidence Range (2.706)
#     1     0.584155      1.22497    (-0.331196,0.309617)
#
!XSPEC12> error 3
# Parameter   Confidence Range (2.706)
#     3    0.0105638    0.0154577    (-0.00247986,0.00241399)
#
!XSPEC12> flux 15.0 350.0 err 100 90
#Parameter distribution is derived from fit covariance matrix.
# Model Flux    2.1261 photons (3.8451e-07 ergs/cm^2/s) range (15.000 - 350.00 keV)
#     Error range     1.803 - 2.597    (2.930e-07 - 5.530e-07)  (90.00% confidence)
#
!XSPEC12> flux 15.0 150.0 err 100 90
#Parameter distribution is derived from fit covariance matrix.
# Model Flux    1.4974 photons (1.4554e-07 ergs/cm^2/s) range (15.000 - 150.00 keV)
#     Error range     1.213 - 1.788    (1.202e-07 - 1.780e-07)  (90.00% confidence)
#
!XSPEC12> flux 15.0 25.0 err 100 90
#Parameter distribution is derived from fit covariance matrix.
# Model Flux   0.30748 photons (9.6616e-09 ergs/cm^2/s) range (15.000 - 25.000 keV)
#     Error range    0.2055 - 0.4882    (6.502e-09 - 1.524e-08)  (90.00% confidence)
#
!XSPEC12> flux 25.0 50.0 err 100 90
#Parameter distribution is derived from fit covariance matrix.
# Model Flux   0.43904 photons (2.5456e-08 ergs/cm^2/s) range (25.000 - 50.000 keV)
#     Error range    0.3470 - 0.5520    (2.024e-08 - 3.164e-08)  (90.00% confidence)
#
!XSPEC12> flux 50.0 100.0 err 100 90
#Parameter distribution is derived from fit covariance matrix.
# Model Flux   0.46558 photons (5.399e-08 ergs/cm^2/s) range (50.000 - 100.00 keV)
#     Error range    0.3791 - 0.5446    (4.387e-08 - 6.283e-08)  (90.00% confidence)
#
!XSPEC12> flux 100.0 150.0 err 100 90
#Parameter distribution is derived from fit covariance matrix.
# Model Flux   0.28528 photons (5.6428e-08 ergs/cm^2/s) range (100.00 - 150.00 keV)
#     Error range    0.2166 - 0.3938    (4.271e-08 - 7.818e-08)  (90.00% confidence)
#
!XSPEC12> flux 100.0 350.0 err 100 90
#Parameter distribution is derived from fit covariance matrix.
# Model Flux   0.91401 photons (2.954e-07 ergs/cm^2/s) range (100.00 - 350.00 keV)
#     Error range    0.5892 - 1.371    (1.833e-07 - 4.683e-07)  (90.00% confidence)
#
!XSPEC12> log none
#