#XSPEC version: 12.9.0c #Build Date/Time: Wed Jul 29 15:14:04 2015 # !XSPEC12>show; # #XSPEC version: 12.9.0c # #Fri Dec 25 10:58:31 2015 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue # Always calculate parameter derivatives using full (slower) numerical differentiation: No # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-unknown-linux-gnu-libc2.12/../spectral/modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Energy # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger444912/remake_spec_cflux/spec_time_resolved//resolved_spec_15/sw00444912000b_avg.rsp associated with spectrum 1 source 1 # energies: 204 channels: 80 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger444912/remake_spec_cflux/spec_time_resolved//resolved_spec_15/sw00444912000b_avg.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger444912/remake_spec_cflux/spec_time_resolved//resolved_spec_15/sw00444912000b_avg.pha #Net count rate (cts/s) for Spectrum:1 8.221e-02 +/- 5.722e-03 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 4-62 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 2.968 sec # Using fit statistic: chi # Using test statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger444912/remake_spec_cflux/spec_time_resolved//resolved_spec_15/sw00444912000b_avg.rsp for Source 1 # # Spectral data counts: 0.243988 # Model predicted rate: 9.82898E-02 # # #Current model list: # #======================================================================== #Model cpflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cpflux Emin keV 100.000 frozen # 2 1 cpflux Emax keV 150.000 frozen # 3 1 cpflux Flux 8.00390E-02 +/- 1.78039E-02 # 4 2 cutep50 a 1.48943 +/- 0.371971 # 5 2 cutep50 b 9999.36 +/- 2.94195E+06 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared = 53.21 using 59 PHA bins. # #Test statistic : Chi-Squared = 53.21 using 59 PHA bins. # Reduced chi-squared = 0.9502 for 56 degrees of freedom # Null hypothesis probability = 5.811866e-01 # Weighting method: standard # !XSPEC12>error 3; # Parameter Confidence Range (2.706) # Warning: renorm - no variable model to allow renormalization # Parameters #Chi-Squared |beta|/N Lvl 3:Flux 4:a 5:b #43.6401 32.9116 -1 0.0555953 1.01300 108.042 #43.1774 8.29665 -1 0.0591850 1.04399 120.149 #42.8393 0.710886 -1 0.0620335 1.07827 134.250 #42.5831 3.2569 -1 0.0643783 1.11115 150.581 #42.3867 3.97435 -1 0.0663342 1.14144 169.534 #42.2346 4.09601 -1 0.0679754 1.16892 191.669 #42.1155 4.01294 -1 0.0693588 1.19370 217.748 #42.021 3.86578 -1 0.0705310 1.21599 248.828 #41.9454 3.71318 -1 0.0715299 1.23603 286.393 #41.8842 3.58245 -1 0.0723863 1.25406 332.585 #41.8342 3.48783 -1 0.0731251 1.27030 390.588 #41.7931 3.43849 -1 0.0737661 1.28494 465.334 #41.7591 3.44285 -1 0.0743252 1.29816 564.825 #41.731 3.51184 -1 0.0748146 1.31011 702.854 #41.7079 3.6623 -1 0.0752440 1.32090 905.061 #41.6999 3.92204 0 0.0752098 1.32079 957.736 #======================================== # Variances and Principal Axes # 3 4 5 # 2.6743E-05| -0.9973 -0.0736 0.0000 # 1.8092E-02| 0.0736 -0.9973 0.0000 # 1.0422E+08| -0.0000 -0.0000 -1.0000 #---------------------------------------- # #==================================== # Covariance Matrix # 1 2 3 # 3.295e-04 4.879e-03 1.461e+02 # 4.879e-03 2.060e-01 4.427e+03 # 1.461e+02 4.427e+03 1.042e+08 #------------------------------------ # #======================================================================== #Model cpflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cpflux Emin keV 100.000 frozen # 2 1 cpflux Emax keV 150.000 frozen # 3 1 cpflux Flux 7.52098E-02 +/- 1.81532E-02 # 4 2 cutep50 a 1.32079 +/- 0.453904 # 5 2 cutep50 b 957.736 +/- 1.02087E+04 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # #Fit statistic : Chi-Squared = 41.70 using 59 PHA bins. # #Test statistic : Chi-Squared = 41.70 using 59 PHA bins. # Reduced chi-squared = 0.7446 for 56 degrees of freedom # Null hypothesis probability = 9.225829e-01 #***Warning: New best fit found, fit parameters will be set to new values. #***Warning: Identical values of the parameter give different values of the statistic. #Please check your result for the high end of the confidence range. # 3 0.0508234 0.0933166 (-0.0244207,0.0180725) # !XSPEC12>error 4; # Parameter Confidence Range (2.706) # 4 0.718395 2.4807 (-0.603133,1.15918) # !XSPEC12>error 5; # Parameter Confidence Range (2.706) # #***XSPEC Error: Unable to fit when starting with fit statistic = NaN #Error occurred during lower bound error calculation. # #Fit statistic : Chi-Squared = 41.70 using 59 PHA bins. # #Test statistic : Chi-Squared = 41.70 using 59 PHA bins. # Reduced chi-squared = 0.7446 for 56 degrees of freedom # Null hypothesis probability = 9.226335e-01 # Current data and model not fit yet. # !XSPEC12> @/local/data/bat1/alien/Swift_3rdBATcatalog/event/scripts/test_cflux/bat_cutpow_cpflux_100_350kev_fit.xcm # !XSPEC12>log none; #