#XSPEC version: 12.9.0c #Build Date/Time: Wed Jul 29 15:14:04 2015 # !XSPEC12>show; # #XSPEC version: 12.9.0c # #Fri Dec 25 07:25:55 2015 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue # Always calculate parameter derivatives using full (slower) numerical differentiation: No # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-unknown-linux-gnu-libc2.12/../spectral/modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Energy # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger454473/remake_spec_cflux/spec_T100/sw00454473000b_avg.rsp associated with spectrum 1 source 1 # energies: 204 channels: 80 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger454473/remake_spec_cflux/spec_T100/sw00454473000b_avg.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger454473/remake_spec_cflux/spec_T100/sw00454473000b_avg.pha #Net count rate (cts/s) for Spectrum:1 1.434e-02 +/- 1.231e-03 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 4-62 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 66.24 sec # Using fit statistic: chi # Using test statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger454473/remake_spec_cflux/spec_T100/sw00454473000b_avg.rsp for Source 1 # # Spectral data counts: 0.949625 # Model predicted rate: 2.14931E-02 # # #Current model list: # #======================================================================== #Model cflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cflux Emin keV 100.000 frozen # 2 1 cflux Emax keV 350.000 frozen # 3 1 cflux lg10Flux cgs -8.23974 +/- 0.376231 # 4 2 cutep50 a 1.99973 +/- 0.390006 # 5 2 cutep50 b 9999.36 +/- 6.79302E+09 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared = 100.66 using 59 PHA bins. # #Test statistic : Chi-Squared = 100.66 using 59 PHA bins. # Reduced chi-squared = 1.7974 for 56 degrees of freedom # Null hypothesis probability = 2.347281e-04 # Weighting method: standard # !XSPEC12>error 3; # Parameter Confidence Range (2.706) # Warning: renorm - no variable model to allow renormalization # Parameters #Chi-Squared |beta|/N Lvl 3:lg10Flux 4:a 5:b #61.0027 28.8808 -2 -8.27682 1.79199 9999.36 #60.7988 3.69152 -1 -8.28553 1.82125 9999.36 #60.7772 0.629245 -1 -8.29393 1.83760 9999.36 #60.7674 1.76597 -1 -8.30074 1.84795 9999.36 #======================================== # Variances and Principal Axes # 3 4 5 # 8.2217E-04| -0.7933 -0.6089 0.0000 # 4.1373E-02| 0.6089 -0.7933 0.0000 # 2.3422E+14| -0.0000 -0.0000 -1.0000 #---------------------------------------- # #==================================== # Covariance Matrix # 1 2 3 # 2.591e-01 2.472e-01 7.548e+06 # 2.472e-01 3.190e-01 8.280e+06 # 7.548e+06 8.280e+06 2.342e+14 #------------------------------------ # #======================================================================== #Model cflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cflux Emin keV 100.000 frozen # 2 1 cflux Emax keV 350.000 frozen # 3 1 cflux lg10Flux cgs -8.30074 +/- 0.509018 # 4 2 cutep50 a 1.84795 +/- 0.564820 # 5 2 cutep50 b 9999.36 +/- 1.53044E+07 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # #Fit statistic : Chi-Squared = 60.77 using 59 PHA bins. # #Test statistic : Chi-Squared = 60.77 using 59 PHA bins. # Reduced chi-squared = 1.085 for 56 degrees of freedom # Null hypothesis probability = 3.082173e-01 #***Warning: New best fit found, fit parameters will be set to new values. #Apparent non-monotonicity in statistic space detected. #Current bracket values -8.50574, -8.54546 #and delta stat 1.6623, 5.06171 #but latest trial -8.52009 gives 0.372929 #Suggest that you check this result using the steppar command. # 3 -8.5256 -8.1194 (-0.219673,0.186524) # !XSPEC12>error 4; # Parameter Confidence Range (2.706) # 4 1.02826 3.01546 (-0.831545,1.15565) # !XSPEC12>error 5; # Parameter Confidence Range (2.706) # #***XSPEC Error: Unable to fit when starting with fit statistic = NaN #Error occurred during lower bound error calculation. # #Fit statistic : Chi-Squared = 60.75 using 59 PHA bins. # #Test statistic : Chi-Squared = 60.75 using 59 PHA bins. # Reduced chi-squared = 1.085 for 56 degrees of freedom # Null hypothesis probability = 3.086516e-01 # Current data and model not fit yet. # !XSPEC12> /* # !XSPEC12> exit # XSPEC: quit #