Notes:

Time averaged spectrum fit using the average DRM

Power-law model
Time interval is from   -5.600 sec. to    8.400 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.8563     ( -0.263331   0.248692 )
Norm@50keV  : 1.89106E-03    ( -0.000330024   0.000321523 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          57.21 using 59 PHA bins.
# Reduced chi-squared =          1.004 for     57 degrees of freedom 
# Null hypothesis probability =   4.671410e-01
 
Photon flux (15-150 keV)    in 14 sec: 0.266507 ( -0.036889  0.036889 ) ph/cm2/s
Energy fluence (15-150 keV)             : 2.43454e-07 ( -4.15351e-08  4.29423e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from   -5.600 sec. to    8.400 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.05742     ( -1.05722   1.45052 )
Epeak [keV] : 47.3897      ( -47.1732 -47.3891 )
Norm@50keV  : 5.62933E-03    ( -0.00562973   0.0363801 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          55.71 using 59 PHA bins.
# Reduced chi-squared =         0.9949 for     56 degrees of freedom 
# Null hypothesis probability =   4.856560e-01
 
Photon flux (15-150 keV)    in 14 sec: 0.258625 ( -0.038137  0.038359 ) ph/cm2/s
Energy fluence (15-150 keV)             : 2.20556e-07 ( -4.58419e-08  5.25228e-08 ) ergs/cm2
 

1-s peak spectrum fit

Power-law model
Time interval is from    1.400 sec. to    2.400 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.84504     ( -0.510966   0.455955 )
Norm@50keV  : 3.95497E-03    ( -0.00130033   0.00122933 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          68.08 using 59 PHA bins.
# Reduced chi-squared =          1.194 for     57 degrees of freedom 
# Null hypothesis probability =   1.494907e-01
 
Photon flux (15-150 keV)    in 1 sec: 0.554826 ( -0.139679  0.139685 ) ph/cm2/s
Energy fluence (15-150 keV)             : 3.63739e-08 ( -1.1352e-08  1.20478e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from    1.400 sec. to    2.400 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.64002     ( -0.621954   2.1604 )
Epeak [keV] : 72.6463      (   )
Norm@50keV  : 5.22281E-03    (     )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          68.03 using 59 PHA bins.
# Reduced chi-squared =          1.215 for     56 degrees of freedom 
# Null hypothesis probability =   1.300496e-01
 
Photon flux (15-150 keV)    in 1 sec: 0.551144 ( -0.140324  0.141586 ) ph/cm2/s
Energy fluence (15-150 keV)             : 3.54585e-08 ( -1.26109e-08  1.12956e-08 ) ergs/cm2
 

Time-resolved spectra