====================================================================== BAT GRB EVENT DATA PROCESSING REPORT Process Script Ver: batgrbproduct v2.46 Process Start Time (local time): Mon Jan 13 06:04:32 EST 2014 Host Name: batevent1 Current Working Dir: /local/data/batevent/batevent_reproc/trigger517234 ====================================================================== Trigger: 00517234 Segment: 000 BAT Trigger Time: 352880026.624 [s; MET] Trigger Stop: 352880030.72 [s; MET] UTC: 2012-03-08T06:13:38.654560 [includes UTCF correction] Where From?: TDRSS position message BAT RA: 219.077930337103 Dec: 79.7034623843718 [deg; J2000] Catalogged Source?: NO Point Source?: YES GRB Indicated?: YES [ by BAT flight software ] Image S/N Ratio: 8.74 Image Trigger?: NO Rate S/N Ratio: 8.30662386291807 [ if not an image trigger ] Image S/N Ratio: 8.74 Analysis Position: [ source = BAT ] RA: 219.077930337103 Dec: 79.7034623843718 [deg; J2000] Refined Position: [ source = BAT pre-slew burst ] RA: 219.12266054142 Dec: 79.677734855378 [deg; J2000] { 14h 36m 29.4s , +79d 40' 39.8" } +/- 1.31455536765174 [arcmin] (estimated 90% radius based on SNR) +/- 0.425188706623284 [arcmin] (formal 1-sigma fit error) SNR: 20.5794735924838 Angular difference between Flight and Ground position is 1.616649 arcmin Partial Coding Fraction: 0.9765625 [ including projection effects ] Duration T90: 61.2559999227524 +/- 16.8148358036733 Measured from: -19.4639999866486 to: 41.7919999361038 [s; relative to TRIGTIME] T50: 23.1159999966621 +/- 3.68487558487293 Measured from: -6.28400003910065 to: 16.8319999575615 [s; relative to TRIGTIME] Fluence Peak Flux (peak 1 second) Measured from: 0.624000012874603 to: 1.6240000128746 [s; relative to TRIGTIME] Total Fluence Measured from: -24.7520000338554 to: 58.2039999961853 [s; relative to TRIGTIME] Band 1 Band 2 Band 3 Band 4 15-25 25-50 50-100 100-350 keV Total 0.667613 0.803141 0.502276 0.097781 0.045030 0.047349 0.043354 0.041502 [error] Peak 0.023313 0.030163 0.019870 0.001468 0.005007 0.005475 0.005001 0.004647 [error] [ fluence units of on-axis counts / fully illuminated detector ] ======================================================================