Notes:

Time averaged spectrum fit using the average DRM

Power-law model
Time interval is from  -14.200 sec. to   22.184 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.95746     ( -0.136902   0.133917 )
Norm@50keV  : 2.24746E-03    ( -0.000183531   0.000180831 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          51.54 using 59 PHA bins.
# Reduced chi-squared =         0.9042 for     57 degrees of freedom 
# Null hypothesis probability =   6.793818e-01
 
Photon flux (15-150 keV)    in 36.38 sec: 0.330716 ( -0.023204  0.023257 ) ph/cm2/s
Energy fluence (15-150 keV)             : 7.52735e-07 ( -5.87777e-08  5.95391e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from  -14.200 sec. to   22.184 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.95818     ( -0.136956   0.135131 )
Epeak [keV] : 9999.36      (   )
Norm@50keV  : 2.24711E-03    (     )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          51.54 using 59 PHA bins.
# Reduced chi-squared =         0.9203 for     56 degrees of freedom 
# Null hypothesis probability =   6.442980e-01
 
Photon flux (15-150 keV)    in 36.38 sec: 0.330773 ( -0.024578  0.023193 ) ph/cm2/s
Energy fluence (15-150 keV)             : 7.53084e-07 ( -6.35391e-08  5.84798e-08 ) ergs/cm2
 

1-s peak spectrum fit

Power-law model
Time interval is from    0.428 sec. to    1.428 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.98293     ( -0.272934   0.255271 )
Norm@50keV  : 6.60011E-03    ( -0.00115607   0.00112023 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          63.33 using 59 PHA bins.
# Reduced chi-squared =          1.111 for     57 degrees of freedom 
# Null hypothesis probability =   2.631113e-01
 
Photon flux (15-150 keV)    in 1 sec: 0.982396 ( -0.13637  0.136444 ) ph/cm2/s
Energy fluence (15-150 keV)             : 6.08247e-08 ( -9.92561e-09  1.0169e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from    0.428 sec. to    1.428 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.57675     ( -0.808686   1.21621 )
Epeak [keV] : 44.6045      (   )
Norm@50keV  : 1.12373E-02    (     )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          62.86 using 59 PHA bins.
# Reduced chi-squared =          1.123 for     56 degrees of freedom 
# Null hypothesis probability =   2.463216e-01
 
Photon flux (15-150 keV)    in 1 sec: 0.966932 ( -0.141752  0.141558 ) ph/cm2/s
Energy fluence (15-150 keV)             : 5.8475e-08 ( -1.09327e-08  1.11684e-08 ) ergs/cm2
 

Time-resolved spectra