====================================================================== BAT GRB EVENT DATA PROCESSING REPORT Process Script Ver: batgrbproduct v2.46 Process Start Time (local time): Wed Sep 10 17:19:51 EDT 2014 Host Name: batevent1 Current Working Dir: /local/data/batevent/batevent_reproc/trigger559482 ====================================================================== Trigger: 00559482 Segment: 000 BAT Trigger Time: 394345074.368 [s; MET] Trigger Stop: 394345075.392 [s; MET] UTC: 2013-07-01T04:17:43.630460 [includes UTCF correction] Where From?: TDRSS position message BAT RA: 357.215620241738 Dec: 36.099431990312 [deg; J2000] Catalogged Source?: NO Point Source?: YES GRB Indicated?: YES [ by BAT flight software ] Image S/N Ratio: 22.22 Image Trigger?: NO Rate S/N Ratio: 135.14806694881 [ if not an image trigger ] Image S/N Ratio: 22.22 Analysis Position: [ source = BAT ] RA: 357.215620241738 Dec: 36.099431990312 [deg; J2000] Refined Position: [ source = BAT pre-slew burst ] RA: 357.223735416883 Dec: 36.099591237941 [deg; J2000] { 23h 48m 53.7s , +36d 05' 58.5" } +/- 0.758440690399934 [arcmin] (estimated 90% radius based on SNR) +/- 0.20031326778811 [arcmin] (formal 1-sigma fit error) SNR: 45.1501207219042 Angular difference between Flight and Ground position is 0.393537 arcmin Partial Coding Fraction: 0.28125 [ including projection effects ] Duration T90: 4.37999993562698 +/- 0.252634126101044 Measured from: -0.39599996805191 to: 3.98399996757507 [s; relative to TRIGTIME] T50: 2.32400000095367 +/- 0.130598592485389 Measured from: 0.412000000476837 to: 2.73600000143051 [s; relative to TRIGTIME] Fluence Peak Flux (peak 1 second) Measured from: 0.0600000023841858 to: 1.06000000238419 [s; relative to TRIGTIME] Total Fluence Measured from: -1.13999998569489 to: 5.3520000576973 [s; relative to TRIGTIME] Band 1 Band 2 Band 3 Band 4 15-25 25-50 50-100 100-350 keV Total 1.590754 2.607478 2.030967 0.437232 0.046383 0.055394 0.049608 0.030825 [error] Peak 0.375108 0.725822 0.700676 0.184274 0.021307 0.027512 0.027125 0.016700 [error] [ fluence units of on-axis counts / fully illuminated detector ] ======================================================================