Notes:

Time averaged spectrum fit using the average DRM

Power-law model
Time interval is from   -1.140 sec. to    5.352 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.5787     ( -0.0454658   0.0453813 )
Norm@50keV  : 7.39963E-02    ( -0.00197593   0.00197582 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          76.37 using 59 PHA bins.
# Reduced chi-squared =          1.340 for     57 degrees of freedom 
# Null hypothesis probability =   4.432090e-02
 
Photon flux (15-150 keV)    in 6.492 sec: 9.44752 ( -0.27869  0.27931 ) ph/cm2/s
Energy fluence (15-150 keV)             : 4.50535e-06 ( -1.24197e-07  1.24197e-07 ) ergs/cm2
 
Cutoff power-law model
Time interval is from   -1.140 sec. to    5.352 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -0.902599     ( -0.200912   0.210102 )
Epeak [keV] : 89.1621      ( -9.35093 15.3628 )
Norm@50keV  : 0.152299    ( -0.0287345   0.0372382 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          40.05 using 59 PHA bins.
# Reduced chi-squared =         0.7152 for     56 degrees of freedom 
# Null hypothesis probability =   9.468694e-01
 
Photon flux (15-150 keV)    in 6.492 sec: 9.09207 ( -0.29291  0.29402 ) ph/cm2/s
Energy fluence (15-150 keV)             : 4.37621e-06 ( -1.31595e-07  1.31213e-07 ) ergs/cm2
 

1-s peak spectrum fit

Power-law model
Time interval is from    0.060 sec. to    1.060 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.26808     ( -0.0671409   0.0672229 )
Norm@50keV  : 0.144177    ( -0.0059853   0.00598526 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          72.19 using 59 PHA bins.
# Reduced chi-squared =          1.267 for     57 degrees of freedom 
# Null hypothesis probability =   8.465227e-02
 
Photon flux (15-150 keV)    in 1 sec: 17.1038 ( -0.7386  0.7393 ) ph/cm2/s
Energy fluence (15-150 keV)             : 1.43632e-06 ( -6.4175e-08  6.42975e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from    0.060 sec. to    1.060 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -0.655967     ( -0.281713   0.300529 )
Epeak [keV] : 122.632      ( -23.3173 55.8743 )
Norm@50keV  : 0.277369    ( -0.0704392   0.101206 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          57.45 using 59 PHA bins.
# Reduced chi-squared =          1.026 for     56 degrees of freedom 
# Null hypothesis probability =   4.213166e-01
 
Photon flux (15-150 keV)    in 1 sec: 6.05113 ( -1.28509  1.28412 ) ph/cm2/s
Energy fluence (15-150 keV)             : 1.40984e-06 ( -6.68586e-08  6.66823e-08 ) ergs/cm2
 

Time-resolved spectra