Notes:

Time averaged spectrum fit using the average DRM

Power-law model
Time interval is from   -1.928 sec. to   12.408 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.9646     ( -0.190435   0.179694 )
Norm@50keV  : 5.35846E-03    ( -0.000675567   0.000661932 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          51.64 using 59 PHA bins.
# Reduced chi-squared =         0.9059 for     57 degrees of freedom 
# Null hypothesis probability =   6.758036e-01
 
Photon flux (15-150 keV)    in 14.34 sec: 0.791020 ( -0.07782  0.077833 ) ph/cm2/s
Energy fluence (15-150 keV)             : 7.07619e-07 ( -8.43876e-08  8.62324e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from   -1.928 sec. to   12.408 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -0.968204     ( -0.778717   0.950282 )
Epeak [keV] : 43.8469      ( -11.3306 17.9375 )
Norm@50keV  : 1.97697E-02    ( -0.0124904   0.0494408 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          46.63 using 59 PHA bins.
# Reduced chi-squared =         0.8327 for     56 degrees of freedom 
# Null hypothesis probability =   8.095638e-01
 
Photon flux (15-150 keV)    in 14.34 sec: 0.761208 ( -0.080586  0.080798 ) ph/cm2/s
Energy fluence (15-150 keV)             : 6.46918e-07 ( -8.92066e-08  9.53819e-08 ) ergs/cm2
 

1-s peak spectrum fit

Power-law model
Time interval is from    1.324 sec. to    2.324 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -2.05878     ( -0.392056   0.347403 )
Norm@50keV  : 1.09533E-02    ( -0.00284461   0.00270444 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          76.40 using 59 PHA bins.
# Reduced chi-squared =          1.340 for     57 degrees of freedom 
# Null hypothesis probability =   4.413103e-02
 
Photon flux (15-150 keV)    in 1 sec: 1.68915 ( -0.29768  0.29771 ) ph/cm2/s
Energy fluence (15-150 keV)             : 1.01419e-07 ( -2.30508e-08  2.41724e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from    1.324 sec. to    2.324 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -2.12806     ( -0.108793   1.12594 )
Epeak [keV] : 66.5778      (   )
Norm@50keV  : 9.85687E-03    (     )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          76.28 using 59 PHA bins.
# Reduced chi-squared =          1.362 for     56 degrees of freedom 
# Null hypothesis probability =   3.708749e-02
 
Photon flux (15-150 keV)    in 1 sec: 1.66472 (    ) ph/cm2/s
Energy fluence (15-150 keV)             : 0 ( 0  0 ) ergs/cm2
 

Time-resolved spectra