#XSPEC version: 12.9.0c #Build Date/Time: Wed Jul 29 15:14:04 2015 # !XSPEC12>show; # #XSPEC version: 12.9.0c # #Wed Dec 23 19:33:31 2015 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue # Always calculate parameter derivatives using full (slower) numerical differentiation: No # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-unknown-linux-gnu-libc2.12/../spectral/modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Energy # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger575707/remake_spec_cflux/spec_1speak/sw00575707000b_1speak.rsp associated with spectrum 1 source 1 # energies: 204 channels: 80 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger575707/remake_spec_cflux/spec_1speak/sw00575707000b_1speak.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger575707/00575707000-results/pha/sw00575707000b_peak.pha #Net count rate (cts/s) for Spectrum:1 2.963e-02 +/- 9.837e-03 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 4-62 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 1 sec # Using fit statistic: chi # Using test statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger575707/remake_spec_cflux/spec_1speak/sw00575707000b_1speak.rsp for Source 1 # # Spectral data counts: 0.0296335 # Model predicted rate: 2.93466E-02 # # #Current model list: # #======================================================================== #Model cpflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cpflux Emin keV 100.000 frozen # 2 1 cpflux Emax keV 350.000 frozen # 3 1 cpflux Flux 1.02665E-05 +/- 6.36063E-05 # 4 2 cutep50 a -9.49998 +/- 8.56637 # 5 2 cutep50 b 40.9478 +/- 4.85718 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared = 55.65 using 59 PHA bins. # #Test statistic : Chi-Squared = 55.65 using 59 PHA bins. # Reduced chi-squared = 0.9937 for 56 degrees of freedom # Null hypothesis probability = 4.880761e-01 # Weighting method: standard # !XSPEC12>error 3; # Parameter Confidence Range (2.706) #***Warning: Zero alpha-matrix diagonal element for parameter 4 #***Warning: Zero alpha-matrix diagonal element for parameter 5 # Parameter 4 is pegged at -9.49998 due to zero or negative pivot element, likely # caused by the fit being insensitive to the parameter. # Parameter 5 is pegged at 40.9478 due to zero or negative pivot element, likely # caused by the fit being insensitive to the parameter. # #***XSPEC Error: No variable parameters for fit # Fit error occurred during lower bound error calculation. # 3 0 0.0231975 (-1.02678e-05,0.0231872) # !XSPEC12>error 4; # Parameter Confidence Range (2.706) # Warning: renorm - no variable model to allow renormalization # Parameters #Chi-Squared |beta|/N Lvl 3:Flux 4:a 5:b #55.548 93.067 0 8.23959e-06 -10.0000 41.0619 #55.5417 14232.1 0 8.17923e-06 -10.0000 41.0768 #======================================== # Variances and Principal Axes # 3 4 5 # 3.7971E-12| -1.0000 0.0000 0.0000 # 1.9242E+01| 0.0000 -0.0830 0.9965 # 3.4074E+02| -0.0000 -0.9965 -0.0830 #---------------------------------------- # #==================================== # Covariance Matrix # 1 2 3 # 2.716e-09 9.057e-04 1.460e-04 # 9.057e-04 3.385e+02 2.659e+01 # 1.460e-04 2.659e+01 2.146e+01 #------------------------------------ # #======================================================================== #Model cpflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cpflux Emin keV 100.000 frozen # 2 1 cpflux Emax keV 350.000 frozen # 3 1 cpflux Flux 8.17923E-06 +/- 5.21126E-05 # 4 2 cutep50 a -10.0000 +/- 18.3991 # 5 2 cutep50 b 41.0768 +/- 4.63208 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # #Fit statistic : Chi-Squared = 55.54 using 59 PHA bins. # #Test statistic : Chi-Squared = 55.54 using 59 PHA bins. # Reduced chi-squared = 0.9918 for 56 degrees of freedom # Null hypothesis probability = 4.921559e-01 #***Warning: New best fit found, fit parameters will be set to new values. # #***Warning: Number of trials exceeded before bracketing of delta fit-stat. #Last attempt: -6.18986e+14, with delta statistic: 0 # # #*** Parameter lower bound is INVALID. # # #***Warning: Number of trials exceeded before bracketing of delta fit-stat. #Last attempt: -6.18986e+14, with delta statistic: 0 # # #*** Parameter upper bound is INVALID. # # 4 0 0 (10,10) # !XSPEC12>error 5; # Parameter Confidence Range (2.706) # #***XSPEC Error: A fit statistic = NaN was encountered, possibly from model calculation error. Fit unable to continue #Error occurred during lower bound error calculation. # #Fit statistic : Chi-Squared = 55.54 using 59 PHA bins. # #Test statistic : Chi-Squared = 55.54 using 59 PHA bins. # Reduced chi-squared = 0.9918 for 56 degrees of freedom # Null hypothesis probability = 4.921733e-01 # Current data and model not fit yet. # !XSPEC12> @/local/data/bat1/alien/Swift_3rdBATcatalog/event/scripts/test_cflux/bat_cutpow_cflux_15_350kev_fit.xcm # !XSPEC12>log none; #