====================================================================== BAT GRB EVENT DATA PROCESSING REPORT Process Script Ver: batgrbproduct v2.46 Process Start Time (local time): Sun Oct 5 00:32:23 EDT 2014 Host Name: batevent1 Current Working Dir: /local/data/batevent/batevent_reproc/trigger590206 ====================================================================== Trigger: 00590206 Segment: 000 BAT Trigger Time: 415632162.816 [s; MET] Trigger Stop: 415632163.84 [s; MET] UTC: 2014-03-04T13:22:31.098380 [includes UTCF correction] Where From?: TDRSS position message BAT RA: 30.668351779433 Dec: 33.4854421100489 [deg; J2000] Catalogged Source?: NO Point Source?: YES GRB Indicated?: YES [ by BAT flight software ] Image S/N Ratio: 11.82 Image Trigger?: NO Rate S/N Ratio: 25.6124969497314 [ if not an image trigger ] Image S/N Ratio: 11.82 Analysis Position: [ source = BAT ] RA: 30.668351779433 Dec: 33.4854421100489 [deg; J2000] Refined Position: [ source = BAT pre-slew burst ] RA: 30.6491075134771 Dec: 33.4730437755863 [deg; J2000] { 02h 02m 35.8s , +33d 28' 23.0" } +/- 0.937426353573178 [arcmin] (estimated 90% radius based on SNR) +/- 0.251066162817423 [arcmin] (formal 1-sigma fit error) SNR: 33.3586259394506 Angular difference between Flight and Ground position is 1.216928 arcmin Partial Coding Fraction: 0.7421875 [ including projection effects ] Duration T90: 14.7839999198914 +/- 1.40137072052854 Measured from: -2.19199997186661 to: 12.5919999480247 [s; relative to TRIGTIME] T50: 9.17599999904633 +/- 0.885889390557535 Measured from: 1.05199998617172 to: 10.227999985218 [s; relative to TRIGTIME] Fluence Peak Flux (peak 1 second) Measured from: 10.2240000367165 to: 11.2240000367165 [s; relative to TRIGTIME] Total Fluence Measured from: -3.81999999284744 to: 13.4920000433922 [s; relative to TRIGTIME] Band 1 Band 2 Band 3 Band 4 15-25 25-50 50-100 100-350 keV Total 0.392416 0.594232 0.546225 0.125853 0.024927 0.026358 0.023220 0.018628 [error] Peak 0.043113 0.081142 0.067755 0.019520 0.006310 0.007061 0.006326 0.004764 [error] [ fluence units of on-axis counts / fully illuminated detector ] ======================================================================