Analysis Summary
Notes:
- 1) No attempt has been made to eliminate the non-significant decimal places.
- 2) This batgrbproduct analysis is done using the HEASARC data.
- 3) This batgrbproduct analysis is using the flight position for the mask-weighting calculation.
ADD SPECIAL NOTE BY HAND
==========================================================================
BAT GROUND-DETECTED GRB DATA PROCESSING REPORT
Process Script Ver: batgrbproduct v2.46
Process Start Time: Thu Dec 17 13:30:10 EST 2015
Host Name: bat1
Current Working Dir: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger601292
======================================================================
Trigger: 00601292 Segment: 000
BAT Trigger Time: 424151476.8
UTC: 2014-06-11T03:51:04.676 [includes UTCF correction]
Where From?: Ground analysis (best_duration.txt)
NOTE: BAT trigger time for ground-detected burst is the T100 start time.
Analysis Position: [ source = GCN ]
RA: 349.939 Dec: -40.111 [deg; J2000]
Refined Position: [ source = BAT pre-slew image ]
RA: 349.923651638 Dec: -40.0988877974 [deg; J2000]
{ 23h 19m 41.7s , -40d -5' -56.0" }
+/- 3.05307891987 [arcmin] (estimated 90% radius based on SNR)
SNR: 6.17578682625
Angular difference between the analysis and refined position is 1.012063 arcmin
Partial Coding Fraction: 0.0300293 [ including projection effects ]
Duration
T90: 3.19999998807907 +/- 1.6
Measured from: 0
to: 3.2 [s; relative to TRIGTIME]
T50: 3.19999998807907 +/- 1.6
Measured from: 0
to: 3.2 [s; relative to TRIGTIME]
====== Table of the duration information =============================
Value tstart tstop
T100 3.200 0.000 3.200
T90 3.200 0.000 3.200
T50 3.200 0.000 3.200
Peak 1.000 0.300 1.300
====== Spectral Analysis Summary =====================================
Model : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index : photon index: E^{Ph_index}
Ph_90err : 90% error of the photon index
Epeak : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm : normalization at 50 keV in both the PL model and CPL model
Nomr_90err : 90% error of the normalization
chi2 : Chi-Squared
dof : degree of freedo
=== Time-averaged spectral analysis ===
(Best model with acceptable fit: N/A)
Model Ph_index Ph_90err_low Ph_90err_hi Epeak Epeak_90err_low Epeak_90err_hi Norm Nomr_90err_low Norm_90err_hi chi2 dof
PL N/A N/A N/A - - - N/A N/A N/A N/A N/A
CPL N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
=== 1-s peak spectral analysis ===
(Best model with acceptable fit: N/A)
Model Ph_index Ph_90err_low Ph_90err_hi Epeak Epeak_90err_low Epeak_90err_hi Norm Nomr_90err_low Norm_90err_hi chi2 dof
PL N/A N/A N/A - - - N/A N/A N/A N/A N/A
CPL N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
=== Fluence/Peak Flux Summary ===
Model Band1 Band2 Band3 Band4 Band5 Total
15-25 25-50 50-100 100-350 15-150 15-350 keV
Fluence PL N/A N/A N/A N/A N/A N/A erg/cm2
Special notes of this burst