Notes:

Time averaged spectrum fit using the average DRM

Power-law model
Time interval is from   -2.860 sec. to   36.480 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.79834     ( -0.213872   0.205208 )
Norm@50keV  : 1.67305E-03    ( -0.000220207   0.000214682 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          41.74 using 59 PHA bins.
# Reduced chi-squared =         0.7323 for     57 degrees of freedom 
# Null hypothesis probability =   9.354084e-01
 
Photon flux (15-150 keV)    in 39.34 sec: 0.230407 ( -0.025627  0.025641 ) ph/cm2/s
Energy fluence (15-150 keV)             : 6.06056e-07 ( -8.03366e-08  8.17945e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from   -2.860 sec. to   36.480 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.80469     ( -0.210769   0.727598 )
Epeak [keV] : 9999.36      ( -9999.35 -9999.36 )
Norm@50keV  : 1.66811E-03    ( -0.000761685   0.00248608 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          41.74 using 59 PHA bins.
# Reduced chi-squared =         0.7454 for     56 degrees of freedom 
# Null hypothesis probability =   9.218283e-01
 
Photon flux (15-150 keV)    in 39.34 sec: 0.231003 ( -0.027922  0.026414 ) ph/cm2/s
Energy fluence (15-150 keV)             : 6.10344e-07 ( -1.03057e-07  6.31816e-08 ) ergs/cm2
 

1-s peak spectrum fit

Power-law model
Time interval is from    5.800 sec. to    6.800 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.92374     ( -0.642354   0.53639 )
Norm@50keV  : 4.09380E-03    ( -0.00155178   0.00138386 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          59.36 using 59 PHA bins.
# Reduced chi-squared =          1.041 for     57 degrees of freedom 
# Null hypothesis probability =   3.897269e-01
 
Photon flux (15-150 keV)    in 1 sec: 0.593554 ( -0.159885  0.159891 ) ph/cm2/s
Energy fluence (15-150 keV)             : 3.76556e-08 ( -1.27217e-08  1.32658e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from    5.800 sec. to    6.800 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -3.41212     ( -0.46828   1.97106 )
Epeak [keV] : 380.842      (   )
Norm@50keV  : 7.98873E-04    (     )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          57.52 using 59 PHA bins.
# Reduced chi-squared =          1.027 for     56 degrees of freedom 
# Null hypothesis probability =   4.186935e-01
 
Photon flux (15-150 keV)    in 1 sec: 0.499182 ( -0.257657  0.237849 ) ph/cm2/s
Energy fluence (15-150 keV)             : 3.3655e-08 ( -1.72744e-08  1.31821e-08 ) ergs/cm2
 

Time-resolved spectra