#XSPEC version: 12.9.0c #Build Date/Time: Wed Jul 29 15:14:04 2015 # !XSPEC12>show; # #XSPEC version: 12.9.0c # #Tue Dec 22 19:59:46 2015 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue # Always calculate parameter derivatives using full (slower) numerical differentiation: No # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-unknown-linux-gnu-libc2.12/../spectral/modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Energy # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger657564/remake_spec_cflux/spec_1speak/sw00657564000b_1speak.rsp associated with spectrum 1 source 1 # energies: 204 channels: 80 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger657564/remake_spec_cflux/spec_1speak/sw00657564000b_1speak.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger657564/00657564000-results/pha/sw00657564000b_peak.pha #Net count rate (cts/s) for Spectrum:1 5.579e-02 +/- 1.125e-02 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 4-62 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 1 sec # Using fit statistic: chi # Using test statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger657564/remake_spec_cflux/spec_1speak/sw00657564000b_1speak.rsp for Source 1 # # Spectral data counts: 0.0557931 # Model predicted rate: 4.42237E-02 # # #Current model list: # #======================================================================== #Model cflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cflux Emin keV 50.0000 frozen # 2 1 cflux Emax keV 100.000 frozen # 3 1 cflux lg10Flux cgs -8.50654 +/- 0.785644 # 4 2 cutep50 a 1.98926 +/- 2.29310E-48 # 5 2 cutep50 b 0.508167 +/- 0.899815 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared = 77.89 using 59 PHA bins. # #Test statistic : Chi-Squared = 77.89 using 59 PHA bins. # Reduced chi-squared = 1.391 for 56 degrees of freedom # Null hypothesis probability = 2.816621e-02 # Weighting method: standard # !XSPEC12>error 3; # Parameter Confidence Range (2.706) # Warning: renorm - no variable model to allow renormalization # Parameters #Chi-Squared |beta|/N Lvl 3:lg10Flux 4:a 5:b #77.6922 1.75895e+38 0 -8.41479 1.98926 0.612740 #======================================== # Variances and Principal Axes # 3 4 5 # 2.2658E-40| -1.0000 -0.0000 -0.0000 # 1.9963E-78| 0.0000 -1.0000 0.0000 # 0.0000E+00| 0.0000 -0.0000 -1.0000 #---------------------------------------- # #==================================== # Covariance Matrix # 1 2 3 # 5.778e-01 -2.421e-39 9.302e-01 # -2.421e-39 1.244e-77 -3.795e-39 # 9.302e-01 -3.795e-39 1.533e+00 #------------------------------------ # #======================================================================== #Model cflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cflux Emin keV 50.0000 frozen # 2 1 cflux Emax keV 100.000 frozen # 3 1 cflux lg10Flux cgs -8.41479 +/- 0.760155 # 4 2 cutep50 a 1.98926 +/- 3.52705E-39 # 5 2 cutep50 b 0.612740 +/- 1.23832 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # #Fit statistic : Chi-Squared = 77.69 using 59 PHA bins. # #Test statistic : Chi-Squared = 77.69 using 59 PHA bins. # Reduced chi-squared = 1.387 for 56 degrees of freedom # Null hypothesis probability = 2.913838e-02 #***Warning: New best fit found, fit parameters will be set to new values. # Warning: renorm - no variable model to allow renormalization # Parameters #Chi-Squared |beta|/N Lvl 3:lg10Flux 4:a 5:b #77.5915 1.4008e+19 0 -8.28332 1.98926 1.05835 #======================================== # Variances and Principal Axes # 3 4 5 # 1.3756E-21| -1.0000 -0.0000 -0.0000 # 9.3295E-41| 0.0000 -1.0000 0.0000 # 0.0000E+00| 0.0000 -0.0000 -1.0000 #---------------------------------------- # #==================================== # Covariance Matrix # 1 2 3 # 7.902e-01 -3.034e-20 3.592e+00 # -3.034e-20 1.272e-39 -1.358e-19 # 3.592e+00 -1.358e-19 1.666e+01 #------------------------------------ # #======================================================================== #Model cflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cflux Emin keV 50.0000 frozen # 2 1 cflux Emax keV 100.000 frozen # 3 1 cflux lg10Flux cgs -8.28332 +/- 0.888940 # 4 2 cutep50 a 1.98926 +/- 3.56692E-20 # 5 2 cutep50 b 1.05835 +/- 4.08148 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # #Fit statistic : Chi-Squared = 77.59 using 59 PHA bins. # #Test statistic : Chi-Squared = 77.59 using 59 PHA bins. # Reduced chi-squared = 1.386 for 56 degrees of freedom # Null hypothesis probability = 2.965130e-02 #***Warning: New best fit found, fit parameters will be set to new values. # #***XSPEC Error: A fit statistic = NaN was encountered, possibly from model calculation error. Fit unable to continue #Error occurred during upper bound error calculation. # #Fit statistic : Chi-Squared = 77.59 using 59 PHA bins. # #Test statistic : Chi-Squared = 77.59 using 59 PHA bins. # Reduced chi-squared = 1.386 for 56 degrees of freedom # Null hypothesis probability = 2.965130e-02 # Current data and model not fit yet. # !XSPEC12> @/local/data/bat1/alien/Swift_3rdBATcatalog/event/scripts/test_cflux/bat_cutpow_cflux_100_150kev_fit.xcm # !XSPEC12>log none; #