#XSPEC version: 12.9.0i #Build Date/Time: Tue Feb 9 12:39:18 2016 # !XSPEC12>show; # #XSPEC version: 12.9.0i # #Mon Mar 28 14:33:22 2016 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue # Always calculate parameter derivatives using full (slower) numerical differentiation: No # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-unknown-linux-gnu-libc2.12/../spectral/modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Energy # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger679120/remake_spec_cflux/spec_1speak/sw00679120000b_1speak.rsp associated with spectrum 1 source 1 # energies: 204 channels: 80 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger679120/remake_spec_cflux/spec_1speak/sw00679120000b_1speak.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger679120/00679120000-results/pha/sw00679120000b_peak.pha #Net count rate (cts/s) for Spectrum:1 1.191e-01 +/- 1.175e-02 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 4-62 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 1 sec # Using fit statistic: chi # Using test statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger679120/remake_spec_cflux/spec_1speak/sw00679120000b_1speak.rsp for Source 1 # # Spectral data counts: 0.119075 # Model predicted rate: 0.114432 # # #Current model list: # #======================================================================== #Model cpflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cpflux Emin keV 15.0000 frozen # 2 1 cpflux Emax keV 150.000 frozen # 3 1 cpflux Flux 0.918153 +/- 9.54849E-02 # 4 2 cutep50 a 1.55302 +/- 0.613572 # 5 2 cutep50 b 9999.36 +/- 5.33997E+06 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared = 69.05 using 59 PHA bins. # #Test statistic : Chi-Squared = 69.05 using 59 PHA bins. # Reduced chi-squared = 1.233 for 56 degrees of freedom # Null hypothesis probability = 1.129943e-01 # Weighting method: standard # !XSPEC12>error 3; # Parameter Confidence Range (2.706) # 3 0.758739 1.06421 (-0.158819,0.146648) # !XSPEC12>error 4; # Parameter Confidence Range (2.706) # 4 1.07295 1.83414 (-0.475326,0.285863) # !XSPEC12>error 5; # Parameter Confidence Range (2.706) # Warning: renorm - no variable model to allow renormalization # Parameters #Chi-Squared |beta|/N Lvl 3:Flux 4:a 5:b #68.9865 0.00973331 2 0.908417 1.50479 9999.36 #======================================== # Variances and Principal Axes # 3 4 5 # 8.3198E-03| -0.9920 0.1263 -0.0000 # 3.2754E-02| 0.1263 0.9920 -0.0000 # 2.2319E+13| 0.0000 0.0000 1.0000 #---------------------------------------- # #==================================== # Covariance Matrix # 1 2 3 # 9.117e-03 1.497e-02 9.534e+04 # 1.497e-02 3.805e-01 2.787e+06 # 9.534e+04 2.787e+06 2.232e+13 #------------------------------------ # #======================================================================== #Model cpflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cpflux Emin keV 15.0000 frozen # 2 1 cpflux Emax keV 150.000 frozen # 3 1 cpflux Flux 0.908417 +/- 9.54829E-02 # 4 2 cutep50 a 1.50479 +/- 0.616841 # 5 2 cutep50 b 9999.36 +/- 4.72433E+06 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # #Fit statistic : Chi-Squared = 68.99 using 59 PHA bins. # #Test statistic : Chi-Squared = 68.99 using 59 PHA bins. # Reduced chi-squared = 1.232 for 56 degrees of freedom # Null hypothesis probability = 1.140561e-01 #***Warning: New best fit found, fit parameters will be set to new values. # #***XSPEC Error: Unable to fit when starting with fit statistic = NaN #Error occurred during lower bound error calculation. # #Fit statistic : Chi-Squared = 68.99 using 59 PHA bins. # #Test statistic : Chi-Squared = 68.99 using 59 PHA bins. # Reduced chi-squared = 1.232 for 56 degrees of freedom # Null hypothesis probability = 1.140561e-01 # Current data and model not fit yet. # !XSPEC12> @/local/data/bat1/alien/Swift_3rdBATcatalog/event/scripts/test_cflux/bat_cutpow_cpflux_15_25kev_fit.xcm # !XSPEC12>log none; #