Notes:

Time averaged spectrum fit using the average DRM

Power-law model
Time interval is from   -2.136 sec. to   13.888 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.92594     ( -0.244537   0.230157 )
Norm@50keV  : 4.04506E-03    ( -0.000581736   0.000560972 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          66.51 using 59 PHA bins.
# Reduced chi-squared =          1.167 for     57 degrees of freedom 
# Null hypothesis probability =   1.821165e-01
 
Photon flux (15-150 keV)    in 16.02 sec: 0.587045 ( -0.070793  0.07097 ) ph/cm2/s
Energy fluence (15-150 keV)             : 5.96091e-07 ( -8.1879e-08  8.29442e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from   -2.136 sec. to   13.888 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -2.52399     ( -0.22335   0.880404 )
Epeak [keV] : 187.437      (   )
Norm@50keV  : 2.04749E-03    (     )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          65.32 using 59 PHA bins.
# Reduced chi-squared =          1.166 for     56 degrees of freedom 
# Null hypothesis probability =   1.845287e-01
 
Photon flux (15-150 keV)    in 16.02 sec: 0.588747 ( -0.109808  0.07068 ) ph/cm2/s
Energy fluence (15-150 keV)             : 5.74887e-07 ( -1.31644e-07  8.58557e-08 ) ergs/cm2
 

1-s peak spectrum fit

Power-law model
Time interval is from    1.508 sec. to    2.508 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.49949     ( -0.505545   0.494606 )
Norm@50keV  : 7.72026E-03    ( -0.00217869   0.00215863 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          54.01 using 59 PHA bins.
# Reduced chi-squared =         0.9476 for     57 degrees of freedom 
# Null hypothesis probability =   5.878833e-01
 
Photon flux (15-150 keV)    in 1 sec: 0.963683 ( -0.277415  0.279677 ) ph/cm2/s
Energy fluence (15-150 keV)             : 7.32538e-08 ( -2.19547e-08  2.23247e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from    1.508 sec. to    2.508 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -0.595282     ( -5.59504   0.556714 )
Epeak [keV] : 77.3895      (   )
Norm@50keV  : 2.19550E-02    (     )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          53.80 using 59 PHA bins.
# Reduced chi-squared =         0.9607 for     56 degrees of freedom 
# Null hypothesis probability =   5.587196e-01
 
Photon flux (15-150 keV)    in 1 sec: 0.916924 ( -0.437457  0.307486 ) ph/cm2/s
Energy fluence (15-150 keV)             : 6.74109e-08 ( -3.34609e-08  2.552e-08 ) ergs/cm2
 

Time-resolved spectra