#XSPEC version: 12.9.1m #Build Date/Time: Wed Aug 16 10:19:00 2017 # !XSPEC12>show # #XSPEC version: 12.9.1m # #Mon Aug 28 20:50:18 2017 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue # Always calculate parameter derivatives using full (slower) numerical differentiation: No # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-unknown-linux-gnu-libc2.12/../spectral/manager/../modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Energy # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger767284/remake_spec_cflux/spec_time_resolved//resolved_spec_19/sw00767284000b_avg.rsp associated with spectrum 1 source 1 # energies: 204 channels: 80 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger767284/remake_spec_cflux/spec_time_resolved//resolved_spec_19/sw00767284000b_avg.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger767284/remake_spec_cflux/spec_time_resolved//resolved_spec_19/sw00767284000b_avg.pha #Net count rate (cts/s) for Spectrum:1 9.750e-03 +/- 3.317e-03 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 4-62 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 9.952 sec # Using fit statistic: chi # Using test statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger767284/remake_spec_cflux/spec_time_resolved//resolved_spec_19/sw00767284000b_avg.rsp for Source 1 # # Spectral data counts: 0.0970354 # Model predicted rate: 9.94847E-03 # # #Current model list: # #======================================================================== #Model cpflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cpflux Emin keV 25.0000 frozen # 2 1 cpflux Emax keV 50.0000 frozen # 3 1 cpflux Flux 2.93431E-02 +/- 1.15017E-02 # 4 2 cutep50 a 0.578961 +/- 2.58623 # 5 2 cutep50 b 65.2585 +/- 68.3991 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared = 60.64 using 59 PHA bins. # #Test statistic : Chi-Squared = 60.64 using 59 PHA bins. # Reduced chi-squared = 1.083 for 56 degrees of freedom # Null hypothesis probability = 3.120959e-01 # Weighting method: standard # !XSPEC12>error 3 # Parameter Confidence Range (2.706) #***Warning: Zero alpha-matrix diagonal element for parameter 4 #***Warning: Zero alpha-matrix diagonal element for parameter 5 # Parameter 4 is pegged at 0.578961 due to zero or negative pivot element, likely # caused by the fit being insensitive to the parameter. # Parameter 5 is pegged at 65.2585 due to zero or negative pivot element, likely # caused by the fit being insensitive to the parameter. # #***XSPEC Error: No variable parameters for fit # Fit error occurred during lower bound error calculation. # 3 0 0.0486093 (-0.0293284,0.0192809) # !XSPEC12>error 4 # Parameter Confidence Range (2.706) # #***Warning: Number of trials exceeded before bracketing of delta fit-stat. #Last attempt: -10, with delta statistic: 1.24634 # # #*** Parameter lower bound is INVALID. # #***Warning: *** 3 point fit failed during interpolation *** #Upper bound error calculation is invalid. # 4 0 0.576575 (-0.576575,0) # !XSPEC12>error 5 # Parameter Confidence Range (2.706) # #***XSPEC Error: Unable to fit when starting with fit statistic = NaN #Error occurred during lower bound error calculation. # #Fit statistic : Chi-Squared = 60.64 using 59 PHA bins. # #Test statistic : Chi-Squared = 60.64 using 59 PHA bins. # Reduced chi-squared = 1.083 for 56 degrees of freedom # Null hypothesis probability = 3.120962e-01 # Current data and model not fit yet. # !XSPEC12> @/local/data/bat1/alien/Swift_3rdBATcatalog/event/scripts/test_cflux/bat_cutpow_cpflux_50_100kev_fit.xcm # !XSPEC12>log none #