====================================================================== BAT GRB EVENT DATA PROCESSING REPORT Process Script Ver: batgrbproduct v2.46 Process Start Time (local time): Wed May 30 16:01:48 EDT 2018 Host Name: bat1 Current Working Dir: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger819301 ====================================================================== Trigger: 00819301 Segment: 000 BAT Trigger Time: 543977901.504 [s; MET] Trigger Stop: 543977909.696 [s; MET] UTC: 2018-03-29T00:58:00.805800 [includes UTCF correction] Where From?: TDRSS position message BAT RA: 329.297998471192 Dec: -15.0707756964668 [deg; J2000] Catalogged Source?: NO Point Source?: YES GRB Indicated?: YES [ by BAT flight software ] Image S/N Ratio: 6.9 Image Trigger?: NO Rate S/N Ratio: 9.59166304662544 [ if not an image trigger ] Image S/N Ratio: 6.9 Analysis Position: [ source = BAT ] RA: 329.297998471192 Dec: -15.0707756964668 [deg; J2000] Refined Position: [ source = BAT pre-slew burst ] RA: 329.296632171678 Dec: -15.1056178798433 [deg; J2000] { 21h 57m 11.2s , -15d 06' 20.2" } +/- 2.49942751046552 [arcmin] (estimated 90% radius based on SNR) +/- 1.29312659436897 [arcmin] (formal 1-sigma fit error) SNR: 8.21816285739399 Angular difference between Flight and Ground position is 2.092029 arcmin Partial Coding Fraction: 0.8125 [ including projection effects ] Duration T90: 36 +/- 7.28010988928052 Measured from: -0.503999948501587 to: 35.4960000514984 [s; relative to TRIGTIME] T50: 19 +/- 11.1803398874989 Measured from: 2.49600005149841 to: 21.4960000514984 [s; relative to TRIGTIME] Fluence Peak Flux (peak 1 second) Measured from: 0.496000051498413 to: 1.49600005149841 [s; relative to TRIGTIME] Total Fluence Measured from: -0.503999948501587 to: 39.4960000514984 [s; relative to TRIGTIME] Band 1 Band 2 Band 3 Band 4 15-25 25-50 50-100 100-350 keV Total 0.232054 0.205690 0.119308 0.023484 0.040123 0.041141 0.035310 0.029233 [error] Peak 0.029043 0.001151 0.023561 0.006947 0.006402 0.006748 0.006034 0.004835 [error] [ fluence units of on-axis counts / fully illuminated detector ] ======================================================================