Notes:

Time averaged spectrum fit using the average DRM

Power-law model
Time interval is from   -1.796 sec. to   15.852 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.81411     ( -0.147382   0.143235 )
Norm@50keV  : 4.74708E-03    ( -0.000428446   0.000421681 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          56.00 using 59 PHA bins.
# Reduced chi-squared =         0.9825 for     57 degrees of freedom 
# Null hypothesis probability =   5.126057e-01
 
Photon flux (15-150 keV)    in 17.65 sec: 0.657787 ( -0.051072  0.0511 ) ph/cm2/s
Energy fluence (15-150 keV)             : 7.71107e-07 ( -7.0145e-08  7.11498e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from   -1.796 sec. to   15.852 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.62861     ( -0.562442   0.611539 )
Epeak [keV] : 89.3582      (   )
Norm@50keV  : 6.01123E-03    (     )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          55.67 using 59 PHA bins.
# Reduced chi-squared =         0.9941 for     56 degrees of freedom 
# Null hypothesis probability =   4.873852e-01
 
Photon flux (15-150 keV)    in 17.65 sec: 0.652226 ( -0.053692  0.05351 ) ph/cm2/s
Energy fluence (15-150 keV)             : 7.56214e-07 ( -8.25016e-08  8.12662e-08 ) ergs/cm2
 

1-s peak spectrum fit

Power-law model
Time interval is from    1.024 sec. to    2.024 sec.
 
Spectral model in power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.20429     ( -0.365754   0.383372 )
Norm@50keV  : 9.05344E-03    ( -0.00165752   0.00165735 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          57.84 using 59 PHA bins.
# Reduced chi-squared =          1.015 for     57 degrees of freedom 
# Null hypothesis probability =   4.439689e-01
 
Photon flux (15-150 keV)    in 1 sec: 1.06333 ( -0.20264  0.20346 ) ph/cm2/s
Energy fluence (15-150 keV)             : 9.17508e-08 ( -1.90097e-08  1.92203e-08 ) ergs/cm2
 
Cutoff power-law model
Time interval is from    1.024 sec. to    2.024 sec.
Spectral model in the cutoff power-law:
------------------------------------------------------------
Parameters  : value       lower 90%   higher 90%
Photon index: -1.20155     ( -0.344458   0.412172 )
Epeak [keV] : 1.00000E+04      ( -10000 -10000 )
Norm@50keV  : 9.09559E-03    ( -0.00166515   -0.00909559 )
------------------------------------------------------------
#Fit statistic : Chi-Squared =          57.86 using 59 PHA bins.
# Reduced chi-squared =          1.033 for     56 degrees of freedom 
# Null hypothesis probability =   4.063147e-01
 
Photon flux (15-150 keV)    in 1 sec: 1.06976 ( -0.218146  0.20498 ) ph/cm2/s
Energy fluence (15-150 keV)             : 9.09829e-08 ( -1.82887e-08  1.99116e-08 ) ergs/cm2
 

Time-resolved spectra