#XSPEC version: 12.11.0 #Build Date/Time: Mon Apr 13 12:38:19 2020 # !XSPEC12> show # #XSPEC version: 12.11.0 # #Mon May 18 15:34:32 2020 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue #Using chain rule to calculate statistic derivatives (faster method). # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-pc-linux-gnu-libc2.12/../spectral/manager/../modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Channels # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger965638/remake_spec_cflux/spec_T100/sw00965638000b_avg.rsp associated with spectrum 1 source 1 # energies: 204 channels: 80 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger965638/remake_spec_cflux/spec_T100/sw00965638000b_avg.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger965638/remake_spec_cflux/spec_T100/sw00965638000b_avg.pha #Net count rate (cts/s) for Spectrum:1 1.314e-02 +/- 1.477e-03 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 4-62 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 141.5 sec # Using fit statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger965638/remake_spec_cflux/spec_T100/sw00965638000b_avg.rsp for Source 1 # # Spectral data counts: 1.85932 # Model predicted rate: 1.32443E-02 # # #Current model list: # #======================================================================== #Model npow<1> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 npow PhoIndex 1.40317 +/- 0.189688 # 2 1 npow enorm keV 50.0000 frozen # 3 1 npow norm 9.15706E-04 +/- 9.85840E-05 #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared 49.78 using 59 bins. # #Test statistic : Chi-Squared 49.78 using 59 bins. # Null hypothesis probability of 7.40e-01 with 57 degrees of freedom # !XSPEC12> error 1 # Parameter Confidence Range (2.706) # 1 1.09382 1.70378 (-0.309379,0.300579) # !XSPEC12> error 3 # Parameter Confidence Range (2.706) # 3 0.000753397 0.00107783 (-0.000162308,0.000162129) # !XSPEC12> log none #