#XSPEC version: 12.11.0 #Build Date/Time: Mon Apr 13 12:38:19 2020 # !XSPEC12> show # #XSPEC version: 12.11.0 # #Mon May 18 15:30:34 2020 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue #Using chain rule to calculate statistic derivatives (faster method). # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-pc-linux-gnu-libc2.12/../spectral/manager/../modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Channels # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger966554/remake_spec_cflux/spec_20ms_peak/sw00966554000b_20ms_peak.rsp associated with spectrum 1 source 1 # energies: 204 channels: 10 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger966554/remake_spec_cflux/spec_20ms_peak/sw00966554000b_20ms_peak.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger966554/remake_spec_cflux/spec_20ms_peak/sw00966554000b_20ms_peak.pha #Net count rate (cts/s) for Spectrum:1 1.023e+00 +/- 2.301e-01 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 1-10 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 0.02 sec # Using fit statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger966554/remake_spec_cflux/spec_20ms_peak/sw00966554000b_20ms_peak.rsp for Source 1 # # Spectral data counts: 0.0204662 # Model predicted rate: 0.926914 # # #Current model list: # #======================================================================== #Model cutep50<1> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cutep50 a 0.296749 +/- 2.13977 # 2 1 cutep50 b 49.2203 +/- 20.5967 # 3 1 cutep50 norm 0.429057 +/- 1.18797 #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared 5.44 using 10 bins. # #Test statistic : Chi-Squared 5.44 using 10 bins. # Null hypothesis probability of 6.07e-01 with 7 degrees of freedom # !XSPEC12> error 1 # Parameter Confidence Range (2.706) #***Warning: Parameter pegged at hard limit: -10 # Due to zero model norms, the following fit parameters are temporarily frozen:2 # #***Warning: Number of trials exceeded before convergence. #Current trial values 2.15237, 2.15288 #and delta statistic 1.56765, 6.42097 # # 1 0 2.15255 (-0.283097,1.86945) # !XSPEC12> error 2 # Parameter Confidence Range (2.706) #***Warning: Zero alpha-matrix diagonal element for parameter 1 #***Warning: Zero alpha-matrix diagonal element for parameter 3 # Parameter 1 is pegged at 0.283097 due to zero or negative pivot element, likely # caused by the fit being insensitive to the parameter. # Parameter 3 is pegged at 0.436971 due to zero or negative pivot element, likely # caused by the fit being insensitive to the parameter. # #***XSPEC Error: No variable parameters for fit # Fit error occurred during lower bound error calculation. # #***Warning: Number of trials exceeded before bracketing of delta fit-stat. #Last attempt: 10000, with delta statistic: 0.934653 # # #*** Parameter upper bound is INVALID. # # 2 0 0 (-49.0814,-49.0814) # !XSPEC12> error 3 # Parameter Confidence Range (2.706) # Due to zero model norms, the following fit parameters are temporarily frozen:1 2 # #***XSPEC Error: No variable parameters for fit # Fit error occurred during lower bound error calculation. # #***Warning: Number of trials exceeded before bracketing of delta fit-stat. #Last attempt: 1.02456e+06, with delta statistic: 0.629641 # # #*** Parameter upper bound is INVALID. # # 3 0 0 (-0.438486,-0.438486) # !XSPEC12> log none #