#XSPEC version: 12.12.1 #Build Date/Time: Tue Mar 15 11:46:30 2022 # !XSPEC12>show # #XSPEC version: 12.12.1 # #Fri Nov 11 21:43:14 2022 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue #Using chain rule to calculate statistic derivatives (faster method). # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-pc-linux-gnu-libc2.12/../spectral/manager/../modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Energy # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger1048372/remake_spec_cflux/spec_time_resolved//resolved_spec_6/sw01048372000b_avg.rsp associated with spectrum 1 source 1 # energies: 204 channels: 80 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger1048372/remake_spec_cflux/spec_time_resolved/resolved_spec_6//local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger1048372/remake_spec_cflux/spec_time_resolved//resolved_spec_6/sw01048372000b_avg.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger1048372/remake_spec_cflux/spec_time_resolved//resolved_spec_6/sw01048372000b_avg.pha #Net count rate (cts/s) for Spectrum:1 4.729e-02 +/- 4.991e-03 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 4-62 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 7.628 sec # Using fit statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger1048372/remake_spec_cflux/spec_time_resolved//resolved_spec_6/sw01048372000b_avg.rsp for Source 1 # # Spectral data counts: 0.360758 # Model predicted rate: 4.74362E-02 # # #Current model list: # #======================================================================== #Model cpflux<1>*cutep50<2> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cpflux Emin keV 100.000 frozen # 2 1 cpflux Emax keV 350.000 frozen # 3 1 cpflux Flux 4.65657E-02 +/- 4.71277E-02 # 4 2 cutep50 a 1.54105 +/- 0.709823 # 5 2 cutep50 b 86.4646 +/- 137.727 # 6 2 cutep50 norm 1.00000 frozen #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared 69.10 using 59 bins. # #Test statistic : Chi-Squared 69.10 using 59 bins. # Null hypothesis probability of 1.12e-01 with 56 degrees of freedom # #Bayes is off # # !XSPEC12>error 3 # Parameter Confidence Range (2.706) #***Warning: Zero alpha-matrix diagonal element for parameter 4 #***Warning: Zero alpha-matrix diagonal element for parameter 5 # Parameter 4 is pegged at 1.54105 due to zero or negative pivot element, likely # caused by the fit being insensitive to the parameter. # Parameter 5 is pegged at 86.4646 due to zero or negative pivot element, likely # caused by the fit being insensitive to the parameter. # #***XSPEC Error: No variable parameters for fit # Fit error occurred during lower bound error calculation. #Apparent non-monotonicity in statistic space detected. #Current bracket values 0.0465657, 0.12409 #and delta stat 0, 14.0488 #but latest trial 0.0805897 gives 15.9066 #Suggest that you check this result using the steppar command. # 3 0 0.0853281 (-0.0465657,0.0387624) # !XSPEC12>error 4 # Parameter Confidence Range (2.706) # #***Warning: Number of trials exceeded before convergence. #Current trial values 2.54083, 2.54093 #and delta statistic 2.35038, 12.5941 # # 4 0.167497 2.54084 (-1.37355,0.999789) # !XSPEC12>error 5 # Parameter Confidence Range (2.706) # #***XSPEC Error: Unable to fit when starting with fit statistic = NaN #Error occurred during lower bound error calculation. # #Fit statistic : Chi-Squared 69.10 using 59 bins. # #Test statistic : Chi-Squared 69.10 using 59 bins. # Null hypothesis probability of 1.12e-01 with 56 degrees of freedom # Current data and model not fit yet. # !XSPEC12> @/local/data/bat1/alien/Swift_3rdBATcatalog/event/scripts/test_cflux/bat_cutpow_cflux_15_350kev_fit.xcm # !XSPEC12>log none #