#XSPEC version: 12.12.1 #Build Date/Time: Tue Mar 15 11:46:30 2022 # !XSPEC12> show # #XSPEC version: 12.12.1 # #Fri Nov 11 21:43:39 2022 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue #Using chain rule to calculate statistic derivatives (faster method). # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release/x86_64-pc-linux-gnu-libc2.12/../spectral/manager/../modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Channels # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger1048372/remake_spec_cflux/spec_time_resolved//resolved_spec_8/sw01048372000b_avg.rsp associated with spectrum 1 source 1 # energies: 204 channels: 80 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger1048372/remake_spec_cflux/spec_time_resolved/resolved_spec_8//local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger1048372/remake_spec_cflux/spec_time_resolved//resolved_spec_8/sw01048372000b_avg.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger1048372/remake_spec_cflux/spec_time_resolved//resolved_spec_8/sw01048372000b_avg.pha #Net count rate (cts/s) for Spectrum:1 4.706e-01 +/- 4.035e-02 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 4-62 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 0.224 sec # Using fit statistic: chi # Using Response (RMF) File /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger1048372/remake_spec_cflux/spec_time_resolved//resolved_spec_8/sw01048372000b_avg.rsp for Source 1 # # Spectral data counts: 0.105422 # Model predicted rate: 0.429874 # # #Current model list: # #======================================================================== #Model cutep50<1> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 cutep50 a 1.47203 +/- 0.542739 # 2 1 cutep50 b 9999.14 +/- 3.85733E+06 # 3 1 cutep50 norm 2.73470E-02 +/- 1.71663E-02 #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared 51.37 using 59 bins. # #***Warning: Chi-square may not be valid due to bins with zero variance # in spectrum number: 1 # #Test statistic : Chi-Squared 51.37 using 59 bins. # #***Warning: Chi-square may not be valid due to bins with zero variance # in spectrum number(s): 1 # # Null hypothesis probability of 6.50e-01 with 56 degrees of freedom # #Bayes is off # # !XSPEC12> error 1 # Parameter Confidence Range (2.706) #***Warning: Identical values of the parameter give different values of the statistic. #Please check your result for the low end of the confidence range. # 1 1.14332 1.74269 (-0.328709,0.270669) # !XSPEC12> error 2 # Parameter Confidence Range (2.706) #***Warning: Zero alpha-matrix diagonal element for parameter 1 #***Warning: Zero alpha-matrix diagonal element for parameter 3 # Parameter 1 is pegged at 1.47203 due to zero or negative pivot element, likely # caused by the fit being insensitive to the parameter. # Parameter 3 is pegged at 0.027347 due to zero or negative pivot element, likely # caused by the fit being insensitive to the parameter. # #***XSPEC Error: No variable parameters for fit # Fit error occurred during lower bound error calculation. # #***Warning: Number of trials exceeded before bracketing of delta fit-stat. #Last attempt: 10000, with delta statistic: 0 # # #*** Parameter upper bound is INVALID. # # 2 0 0 (-9999.25,-9999.25) # !XSPEC12> error 3 # Parameter Confidence Range (2.706) # 3 0.023017 0.060229 (-0.00432996,0.0328821) # !XSPEC12> log none #