Analysis Summary

Notes:

======================================================================
                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time: Fri Sep 29 23:35:55 EDT 2023
             Host Name: batproc1
   Current Working Dir: /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger1181187
======================================================================

  Trigger: 01181187      Segment: 000

  BAT Trigger Time: 712205434.944   [s; MET]
      Trigger Stop: 712205435.968   [s; MET]
               UTC: 2023-07-28T02:50:03.222400    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 343.538953466444   Dec: 28.1508318660294  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    9.66
     Image Trigger?:     NO
     Rate S/N Ratio:     15.556349186104  [ if not an image trigger ]
     Image S/N Ratio:    9.66

  Analysis Position:   [ source = BAT ]
    RA: 343.538953466444   Dec: 28.1508318660294  [deg; J2000]

  Refined Position:   [ source = BAT pre-slew burst ]
    RA: 343.514139413016   Dec: 28.1695139122038  [deg; J2000]  
        { 22h 54m 03.4s , +28d 10' 10.3" }
         +/- 1.30088819788565 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.525027114136543 [arcmin] (formal 1-sigma fit error)
    SNR: 20.8890369280975
 
  Angular difference between the analysis and refined position is 1.726099 arcmin
 
  Partial Coding Fraction: 0.4960938    [ including projection effects ]

  Duration
     T90: 14.7599999904633 +/- 0.892307208733889
        Measured from: -4.85199999809265
                   to: 9.90799999237061     [s; relative to TRIGTIME]
     T50: 5.54799997806549 +/- 3.44707409608694
        Measured from: 0.363999962806702
                   to: 5.91199994087219     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 0.407999992370605     
                   to: 1.40799999237061     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: -5.62000000476837     
                   to: 10.7400000095367     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.547540   0.710483   0.508162   0.076881
           0.045459   0.047884   0.041728   0.036886 [error]
 Peak      0.081328   0.117314   0.094351   0.005505
           0.012280   0.013879   0.011885   0.008954 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================
 
 
====== Table of the duration information =============================
 
        Value   tstart    tstop
T100   16.360   -5.620   10.740
T90    14.760   -4.852    9.908
T50     5.548    0.364    5.912
Peak    1.000    0.408    1.408
 
 
====== Spectral Analysis Summary =====================================
 
Model      : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index   : photon index: E^{Ph_index}
Ph_90err   : 90% error of the photon index
Epeak      : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm       : normalization at 50 keV in both the PL model and CPL model
Nomr_90err : 90% error of the normalization
chi2       : Chi-Squared
dof        : degree of freedo
 
=== Time-averaged spectral analysis ===
(Best model with acceptable fit: PL)
 
Model Ph_index Ph_90err_low Ph_90err_hi  Epeak  Epeak_90err_low  Epeak_90err_hi  Norm       Nomr_90err_low    Norm_90err_hi    chi2    dof
PL      -1.580    -0.133      0.131       -           -               -         7.33e-03     -5.84e-04          5.80e-04      52.730   57
CPL     -1.088    -0.503      0.570       89.325     -25.964      3148.915      1.32e-02     -5.86e-03          1.26e-02      49.940   56
 
 
=== 1-s peak spectral analysis ===
(Best model with acceptable fit: PL)
 
Model Ph_index Ph_90err_low Ph_90err_hi  Epeak  Epeak_90err_low  Epeak_90err_hi  Norm       Nomr_90err_low    Norm_90err_hi    chi2    dof
PL      -1.581     -0.207     0.200       -           -               -         1.92e-02     -2.62e-03          2.59e-03      56.060   57
CPL     -0.295     -0.902     1.123       64.376     -12.813        40.680      8.94e-02     -8.94e-02          2.44e-01      49.730   56
 
 
=== Fluence/Peak Flux Summary ===
 
              Model    Band1     Band2     Band3     Band4     Band5     Total
                       15-25     25-50    50-100    100-350    15-150    15-350    keV
Fluence         PL   1.65e-07  2.89e-07  3.87e-07  1.06e-06  1.13e-06  1.90e-06   erg/cm2
      90%_error_low -2.01e-08 -2.23e-08 -4.06e-08 -2.16e-07 -9.66e-08 -2.54e-07   erg/cm2
      90%_error_hi   2.07e-08  2.23e-08  4.06e-08  2.51e-07  9.76e-08  2.81e-07   erg/cm2
Peak flux       PL   8.52e-01  8.17e-01  5.46e-01  5.70e-01  2.45e+00  2.79e+00   ph/cm2/s
      90%_error_low -1.62e-01 -1.07e-01 -9.31e-02 -1.68e-01 -3.13e-01 -3.63e-01   ph/cm2/s
      90%_error_hi   1.69e-01  1.06e-01  9.26e-02  2.03e-01  3.14e-01  3.66e-01   ph/cm2/s
 
Fluence        CPL   1.54e-07  3.05e-07  3.95e-07  5.08e-07  1.08e-06  1.36e-06   erg/cm2
      90%_error_low -2.35e-08 -2.77e-08 -4.37e-08 -2.53e-07 -1.07e-07 -2.75e-07   erg/cm2
      90%_error_hi   2.37e-08  2.85e-08  4.42e-08  5.72e-07  1.08e-07  5.70e-07   erg/cm2
Peak flux      CPL   8.26e-01  6.39e-01  3.46e-01  3.21e-01  1.94e+00  2.13e+00   ph/cm2/s
      90%_error_low -2.18e-01 -1.54e-01 -9.11e-02 -7.87e-02 -4.43e-01 -3.56e-01   ph/cm2/s
      90%_error_hi   1.88e-01  1.19e-01  8.29e-02  6.14e-02  3.40e-01  3.14e-01   ph/cm2/s
 
======================================================================