#XSPEC version: 12.13.1 #Build Date/Time: Thu Jul 20 16:52:54 2023 # !XSPEC12> show # #XSPEC version: 12.13.1 # #Sat Mar 9 15:15:54 2024 # Auto-saving is done after every command. # Fit statistic in use: Chi-Squared # Minimization technique: Levenberg-Marquardt # Convergence criterion = 0.01 # Parameter fit deltas: 0.01 * parValue #Using chain rule to calculate statistic derivatives (faster method). # Querying disabled - will not continue fitting. # Prefit-renorming enabled. # Solar abundance table: angr # Photoionization Cross-Section Table: # bcmc: Balucinska-Church and McCammon, 1998 # Cosmology in use: H0 = 70 q0 = 0 Lambda0 = 0.73 # Model data directory: /software/lheasoft/release6.32/x86_64-pc-linux-gnu-libc2.12/../spectral/manager/../modelData/ # Plot settings: # Showing of individual additive components is OFF. # Showing of background spectra is OFF. # Effective area normalization is OFF. # Current unit settings: # Energy = keV # Wavelength = angstrom, with Y-Axis displayed per Hz # X-Axis data display mode: Channels # Spectra plots will be shifted to source frame by redshift value z: 0 # Device: /null # Plotting of line IDs is OFF. # Splashpage is ON. # xlog for data plots is ON. # ylog for data plots is OFF. # # Default plot rebin settings for all plot groups: # Min. Signif. Max. # Bins Error Type # 0.00000 1 quad # # Responses read: # ../sw01210276000b_preslew.rsp associated with spectrum 1 source 1 # energies: 204 channels: 80 # Distinct RMF files: # /local/data/bat1/alien/Swift_3rdBATcatalog/event/batevent_reproc/trigger1210276/01210276000-results/pha/slew_pha/../sw01210276000b_preslew.rsp # #1 file 1 spectrum #Spectrum 1 Spectral Data File: ../sw01210276000b_slew.pha #Net count rate (cts/s) for Spectrum:1 6.987e-03 +/- 1.779e-03 # Assigned to Data Group 1 and Plot Group 1 # Noticed Channels: 4-62 # Telescope: SWIFT Instrument: BAT Channel Type: PI # Exposure Time: 70.6 sec # Using fit statistic: chi # Using Response (RMF) File ../sw01210276000b_preslew.rsp for Source 1 # # Spectral data counts: 0.493309 # Model predicted rate: 6.93684E-03 # # #Current model list: # #======================================================================== #Model npow<1> Source No.: 1 Active/On #Model Model Component Parameter Unit Value # par comp # 1 1 npow PhoIndex 2.67456 +/- 0.601678 # 2 1 npow enorm keV 50.0000 frozen # 3 1 npow norm 2.88093E-04 +/- 1.44980E-04 #________________________________________________________________________ # # Using energies from responses. # #Fit statistic : Chi-Squared 67.83 using 59 bins. # #Test statistic : Chi-Squared 67.83 using 59 bins. # Null hypothesis probability of 1.54e-01 with 57 degrees of freedom # #Bayes is off # # !XSPEC12> flux 20.0 50.0 # Model Flux 0.031305 photons (1.4636e-09 ergs/cm^2/s) range (20.000 - 50.000 keV) # !XSPEC12> flux 50.0 150.0 # Model Flux 0.0072367 photons (8.9549e-10 ergs/cm^2/s) range (50.000 - 150.00 keV) # !XSPEC12> error 1 # Parameter Confidence Range (2.706) # 1 1.81219 5.03757 (-0.862368,2.36301) # !XSPEC12> error 3 # Parameter Confidence Range (2.706) # Due to zero model norms, the following fit parameters are temporarily frozen:1 # #***XSPEC Error: No variable parameters for fit # Fit error occurred during lower bound error calculation. # 3 0 0.000526214 (-0.000288092,0.000238122) # !XSPEC12> flux 15.0 350.0 err 100 90 #Parameter distribution is derived from fit covariance matrix. # Model Flux 0.064274 photons (3.3939e-09 ergs/cm^2/s) range (15.000 - 350.00 keV) # Error range 0.02835 - 0.08985 (1.202e-09 - 9.205e-09) (90.00% confidence) # !XSPEC12> flux 15.0 150.0 err 100 90 #Parameter distribution is derived from fit covariance matrix. # Model Flux 0.063238 photons (3.0389e-09 ergs/cm^2/s) range (15.000 - 150.00 keV) # Error range 0.02393 - 0.08831 (9.820e-10 - 5.356e-09) (90.00% confidence) # !XSPEC12> flux 15.0 25.0 err 100 90 #Parameter distribution is derived from fit covariance matrix. # Model Flux 0.037142 photons (1.1235e-09 ergs/cm^2/s) range (15.000 - 25.000 keV) # Error range 0.000 - 0.05103 (0.000 - 1.518e-09) (90.00% confidence) # !XSPEC12> flux 25.0 50.0 err 100 90 #Parameter distribution is derived from fit covariance matrix. # Model Flux 0.018859 photons (1.0198e-09 ergs/cm^2/s) range (25.000 - 50.000 keV) # Error range 0.001395 - 0.02569 (7.275e-11 - 1.397e-09) (90.00% confidence) # !XSPEC12> flux 50.0 100.0 err 100 90 #Parameter distribution is derived from fit covariance matrix. # Model Flux 0.0059084 photons (6.3899e-10 ergs/cm^2/s) range (50.000 - 100.00 keV) # Error range 0.000 - 0.01164 (0.000 - 1.295e-09) (90.00% confidence) # !XSPEC12> flux 100.0 150.0 err 100 90 #Parameter distribution is derived from fit covariance matrix. # Model Flux 0.0013283 photons (2.565e-10 ergs/cm^2/s) range (100.00 - 150.00 keV) # Error range 0.0001233 - 0.004177 (2.350e-11 - 8.150e-10) (90.00% confidence) # !XSPEC12> flux 100.0 350.0 err 100 90 #Parameter distribution is derived from fit covariance matrix. # Model Flux 0.0023644 photons (6.1151e-10 ergs/cm^2/s) range (100.00 - 350.00 keV) # Error range 6.072e-05 - 0.01661 (1.385e-11 - 4.954e-09) (90.00% confidence) # !XSPEC12> log none #