NOTE: uvot_fluxes_wget.pl vrs. 2018-11-07 fem at 191030d09h22m01s640690usUT NOTE: Source region spec. is: 352.16142 -40.50108 4" NOTE: Used archived XRT position of 352.16142 -40.50108 4.00 NOTE: position reference is GCN_Circulars-26095 =========== Draft Upper Limit Circular ======== GRB 191029A: Swift/UVOT Upper Limits S. R. Oates (U.Warwick) and P. A. Evans (U. Leicester) report on behalf of the Swift/UVOT team: The Swift/UVOT began settled observations of the field of GRB 191029A 3098 s after the BAT trigger (Evans et al., GCN Circ. 26088). No optical afterglow consistent with the XRT position (Evans et al. GCN Circ. 26095) is detected in the initial UVOT exposures. Preliminary 3-sigma upper limits using the UVOT photometric system (Breeveld et al. 2011, AIP Conf. Proc. 1358, 373) for the first finding chart (FC) exposure and subsequent exposures are: Filter T_start(s) T_stop(s) Exp(s) Mag white_FC 3098 3248 147 >21.0 white 3098 22783 1745 >22.2 v 3255 15599 1278 >20.4 b 4075 28520 2549 >21.8 u 3870 27979 2163 >21.2 w1 3665 27066 1805 >21.0 m2 3460 16504 1279 >20.9 w2 4486 11309 868 >21.5 The magnitudes in the table are not corrected for the Galactic extinction due to the reddening of E(B-V) = 0.02 in the direction of the burst (Schlegel et al. 1998).